High-Pressure Stationary Pump
SER 9979-A
Alemite Corporation
3
Revision (4-02)
Changes Since Last Printing
Deleted Connector and Coupler from Air Motor
Assembly
NOTE: Refer to Figure 2 for component
identification on all assembly procedures.
CAUTION
Select a clean environment for all assembly proce-
dures. Prevent contamination from foreign mate-
rial. Damage to components can occur.
Pump Assembly
IMPORTANT: Make sure to remove the pro-
tective cover from the inlet of Pump Assem-
bly (1).
1. Install Pump Assembly (1) into Cover (2).
• Make sure to align the Screw holes.
2. Secure the Pump Assembly to the Cover with Lock
Washers (4) and Screws (5).
• Tighten the Screws securely.
Follower Plate
3. Place Follower Plate (6) onto the top of the product.
• With a wobbling motion, eliminate any air that may
be trapped underneath the Follower Plate. Force the
product through the hole in the center of the Plate.
4. Guide the pump tube into the Follower Plate and fit the
Cover onto the container.
5. Secure the Cover to the container with Thumb
Screws (3).
6. Test/Prime the Pump assembly.
• Refer to Service Guide SER 9630 for details.