![Alemite 8593 Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/alemite/8593-series/8593-series_service-manual_2893761004.webp)
Table 1
Specifications
Tank capacity
105.7 qt
(100 l)
Top of sight gauge
95 qt
(90 l)
Drain bowl capacity
17 qt
(16 l)
Height at highest
position
78 in
(1980 mm)
Height at lowest
position
51 in
(1300 mm)
Fig. 1
Dimensions
Description
Models 8592 and 8593* are portable
non-pressurized drains designed to safely
capture fluids drained from vehicles on ser-
vice lifts.
General safety
standards
The standards listed below must be
observed to prevent injury to operators and
damage to the used fluid drain.
• Read all labels on the used fluid drain
carefully, do not cover them and replace
them immediately if damaged.
• The used fluid drain must only be used by
authorized personal trained in its use.
• Never leave drain unattended when oper-
ating or evacuating.
• Never use drain near open flame or heat
source.
• Never use drain for handling highly volatile
fuels and fluids.
• Do not use acid solutions which could
damage the drain and/or injure persons.
• The drain will remain in place up to a
maximum gradient of 0.5%, before
beginning to slide.
5
1 /
(41 mm)
5
8
4
Inspection
Prior to operation or maintenance, visually
inspect the drain for worn, damaged, loose
and/or missing parts.
If the drain is damaged, badly worn or
operates abnormally, it should be removed
from service. Contact a factory authorized
service center for repair.
An annual tank/component inspection is
recommended to be performed by a factory
authorized service center.
Tank maintenance
The drain does not require any special
maintenance, other than normal cleaning
that should be done with a damp cloth
(water and alcohol or normal detergent for
household appliances made out of plastic).
NOTE
Do not use cleaning solutions that can
damage plastic containers.
NOTE
It is recommended that tank be emptied
and cleaned of all sediments through
frequently scheduled maintenance.
*