Alemite 8593 Series Скачать руководство пользователя страница 4

Table 1

Specifications

Tank capacity

105.7 qt 

(100 l)

Top of sight gauge

95 qt 

(90 l)

Drain bowl capacity

17 qt 

(16 l)

Height at highest 
position

78 in 

(1980 mm)

Height at lowest 
position

51 in 

(1300 mm)

Fig. 1

Dimensions

Description

Models 8592 and 8593* are portable 
non-pressurized drains designed to safely 
capture fluids drained from vehicles on ser-
vice lifts.

General safety 
standards

The standards listed below must be 
observed to prevent injury to operators and 
damage to the used fluid drain.

•  Read all labels on the used fluid drain 

carefully, do not cover them and replace 
them immediately if damaged.

•  The used fluid drain must only be used by 

authorized personal trained in its use.

•  Never leave drain unattended when oper-

ating or evacuating.

•  Never use drain near open flame or heat 

source.

•  Never use drain for handling highly volatile 

fuels and fluids.

•  Do not use acid solutions which could 

damage the drain and/or injure persons.

•  The drain will remain in place up to a  

maximum gradient of 0.5%, before  
beginning to slide.

5

1  /

(41 mm)

5

8

4

Inspection

Prior to operation or maintenance, visually 
inspect the drain for worn, damaged, loose 
and/or missing parts.

If the drain is damaged, badly worn or 

operates abnormally, it should be removed 
from service. Contact a factory authorized 
service center for repair.

An annual tank/component inspection is 

recommended to be performed by a factory 
authorized service center.

Tank maintenance

The drain does not require any special  
maintenance, other than normal cleaning 
that should be done with a damp cloth 
(water and alcohol or normal detergent for 
household appliances made out of plastic).

NOTE

Do not use cleaning solutions that can 
damage plastic containers.

NOTE

It is recommended that tank be emptied 
and cleaned of all sediments through 
frequently scheduled maintenance.

*

  Indicates change.

4

Содержание 8593 Series

Страница 1: ...Service guide Date of issue September 2021 Form number 671048 Version 2 Model 8592 and 8593 Portable used fluid drain Indicates change...

Страница 2: ...signal words for safety 3 Safety 3 Description 4 General safety standards 4 Inspection 4 Specifications 4 Tank maintenance 4 Empty tank 5 Purge tank 5 Parts list 5 Exploded view 6 Service kits availab...

Страница 3: ...ling operating troubleshooting the assembly The assembly must be installed maintained and repaired exclusively by persons familiar with the instructions Install the assembly only after safety instruct...

Страница 4: ...ling highly volatile fuels and fluids Do not use acid solutions which could damage the drain and or injure persons The drain will remain in place up to a maximum gradient of 0 5 before beginning to sl...

Страница 5: ...Evacuate tank of all fluids using evacuation system 2 Remove plug 22 on lower connection 21 3 Flush tank with water and normal detergent until tank bottom is free of all solids and sediments 4 Reinsta...

Страница 6: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 24 25 26 27 28 29 30 31 3 Fig IPB 1 Exploded view 6...

Страница 7: ...26 mm 2 27 Holder seals kit Pin Cotter 1 29 393808 8 Lock ring split 1 15 Wheel Rubber 1 28 Seal 2 in 1 3 O ring 4131 1 15 Sight gauge kit 393808 4 Sight gauge 1 19 Suction pipe kit Adapter 1 2 in ext...

Страница 8: ...en extracts unless prior written permission is granted Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss o...

Отзывы: