Description

Model 8592 is a portable non-pressurized  drain designed to safely 
capture fluids drained from vehicles on service lifts.

Owner/Operator Responsibility

It is the owner/operator responsibility to properly use and maintain 
this equipment. The instructions and warnings contained in this 
manual shall be read and understood by the owner/operator prior to 
operating this equipment. If an owner/operator does not under-
stand English, the contents of this manual shall be explained in the 
owner/operator’s native language to assure that the owner/operator 
comprehends. The owner/operator shall retain this manual for the 
future reference to important warnings, operating and maintenance 
instructions.

General Safety Standards

The Standards listed below must be observed to prevent injury to 
operators and damage to the Used Fluid Drain.

  Read all Labels on the Used Fluid Drain carefully, do not cover 

them and replace them immediately if damaged.

  The Used Fluid Drain must only be used by authorized personal 

trained in its use.

  NEVER leave Drain unattended when operating or evacuating.

  NEVER use Drain near open flame or heat source.

  NEVER use Drain for handling highly volatile fuels and fluids.

  Do not use acid solutions which could damage the Drain and/or 

injure persons.

  The Drain will remain in place up to a maximum gradient of 

0.5%, before beginning to slide.

Inspection

Prior to operation or maintenance, a visual inspection shall be 
made. Check for worn, damaged, loose and/or missing parts.

If the Drain is damaged, badly worn or operates abnormally, it 
should be removed from service. Contact a factory authorized ser -
vice center for repair.

An annual tank/component inspection is recommended to be per-
formed by a factory authorized service center.

Tank Maintenance

The Drain does not require any special maintenance, other than 
normal cleaning, which should be done with a damp cloth (water 
and alcohol or normal detergent for household appliances made out 
of plastic).

C AU T I O N

IMPORTANT!  Do  not  use  cleaning  solutions  that  can  damage 
plastic containers.

Emptying the Tank

Before the tank approaches maximum fill (as seen through the 
Sight-Gauge (5) , empty the tank by connecting Camlock Fitting (20) 
to an Evacuation System. The length of Suction Pipe (22) ensures 
that it clears the tank bottom to prevent solids and sediments from 
being sucked into and damaging the evacuation pump.

C AU T I O N

It is highly recommended that the tank be emptied and cleaned 
of all sediments through frequently scheduled maintenance.

Sediments may build up high enough to start clogging the Suction 
Pipe (22) before the next scheduled tank purge. A stop-gap feature 
has been designed into the Suction Pipe (22) to enable oil evacua-
tion to proceed temporarily (See Figure 3).

1.  Apply a wrench to Camlock Fitting (20) and turn it counter 

clockwise. [If necessary, secure Plug (21) with a pipe wrench to 
hold it stationary.]

2.  Raise the Suction Pipe (22) to a maximum height of 1-5/8 

inches (41mm).

3.  Connect Camlock Fitting (20) to an evacuation system and com-

plete emptying of the tank.

4.  Schedule a tank purge as soon as possible before the tank fills 

up with more sediments and solids.

5.  Upon completion of the tank purge, turn Camlock Fitting (20) 

clockwise as far down as possible to reset the Suction Tube (22) 
height.

Portable Used Fluid Drain 

8592

02-2020

2

Alemite, LLC

Figure 3:

Raising Suction Piping

Содержание 8592

Страница 1: ...8592 8592 FORM 671048 SERVICE GUIDE Alemite LLC 167 Roweland Drive Johnson City Tennessee 37601 USA www alemite com Copyright 2016 by Alemite LLC PORTABLE USED FLUID DRAIN Model 8592...

Страница 2: ...om service Contact a factory authorized ser vice center for repair An annual tank component inspection is recommended to be per formed by a factory authorized service center Tank Maintenance The Drain...

Страница 3: ...3 Flush tank with water on normal detergent until tank bottom is free of all solids and sediments 4 Reinstall Plug 2 and check for leaks 5 Upon completion of the tank purge turn Camlock Fitting 20 clo...

Страница 4: ...ble Used Fluid Drain 8592 02 2020 4 Alemite LLC Parts List 11 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 8 22 23 24 25 26 27 28 29 30 31 Figure 2 Portable Used Fluid Drain Model 8592 Exploded...

Страница 5: ...ob 1 393808 7 13 Fitting Pipe Holder 1 393808 7 14 Drain Tube 1 393808 7 15 Bushing 1 393808 6 16 O Ring 4100 1 393808 5 393808 6 17 343327 Funnel Assembly 1 18 343326 Screen 1 19 Screw SHCap 1 393808...

Страница 6: ...ing Kit Qty Item 393808 5 O Ring 4131 1 11 O Ring 4100 1 15 Funnel Bushing Kit Qty Item 393808 6 Funnel Bushing 1 16 O Ring 4100 1 15 Screw SHCap 1 19 Drain Tube Kit Qty Item 393808 7 Lock ring Split...

Страница 7: ...ssembly using the special bung adapter 343354 The Rotary Hand Pump and the Bung Adapter can be purchased separately Accessories Installation 343354 Step 1 Install 343354 Bung Adapter with indicator gr...

Страница 8: ...www alemite com Alemite LLC 167 Roweland Drive Johnson City Tennessee 37601 USA www alemite com...