background image

SER 8571-5

Portable Hand-Operated Pump

Revision (12-09)

10

Alemite LLC

Troubleshooting Chart

Pump Indications

Possible Problems

Solution

Pump does not cycle

Pump tube jammed and/or contains loose 
components

Rebuild pump tube

Pump will not prime

Pump leaking internally

See 

Internal Leaks

Pump cycles easily

Product source empty

Replenish product

External Leaks

Product leakage visible at 
Packing Nut (

25

)

1. Worn or damaged O-Ring (

26

)

2. Damaged Gasket (

27

)

1. Replace O-Ring (

26

)

2. Replace Gasket (

27

)

Product leakage at bottom 
of Outlet Body (

28

)

1. Tube (

35

) not sufficiently tight

2. Damaged Gasket (

34

)

1. Tighten Tube (

35

) into Outlet Body (

28

)

2. Separate Tube (

35

) from Outlet Body (

28

and replace Gasket (

34

)

Internal Leaks

Pump does not prime

1. Foreign material between Valve (

30

and Plunger Body (

31

)

2. Foreign material between Foot Valve 

(

36

) and Foot Valve Body (

37

)

3. Worn or damaged Valve (

30

)

4. Worn or damaged Plunger Body (

31

)

5. Worn or damaged Foot Valve (

36

)

6. Worn or damaged Foot Valve Body (

37

)

7. Worn or damaged O-Ring (

32

Locate and eliminate source of foreign 
material

Disassemble pump tube, clean, inspect, and 
replace worn or damaged components

Changes Since Last Printing

Replaced Meter

Updated repair parts

1-800-548-1191-http://[email protected]

Содержание 8571-5

Страница 1: ...ual non drip nozzle assembly electronic meter Pump The low pressure pump included with the assembly is designed to dispense automatic transmission fluid directly from their original 16 gallon containe...

Страница 2: ...SER 8571 5 Portable Hand Operated Pump Revision 12 09 2 Alemite LLC Figure 2 Portable Hand Operated Pump Model 8571 Series Exploded View 1 800 548 1191 http www partdeal com info partdeal com...

Страница 3: ...Stop 10 32 1 317809 5F 1 13 339961 1 Pin 1 317860 1 24 14 Cover Assembly w Gasket 1 321203 23 15 Washer Lock 1 4 3 324726 9 16 Nut 1 4 20 3 324742 8 17 Screw Thumb 1 4 28 3 324741 11 18 Nut 8 32 1 32...

Страница 4: ...SER 8571 5 Portable Hand Operated Pump Revision 12 09 4 Alemite LLC Figure 3 Pump Tube Assembly for Model 8571 Series Exploded View 1 800 548 1191 http www partdeal com info partdeal com...

Страница 5: ...ody Plunger 1 172212 14 38 32 O Ring 1 1 4 ID x 1 1 2 OD 1 319320 31 33 Nut Elastic Stop 5 16 18 1 324733 25 34 Gasket 1 324747 30 35 Tube 1 326784 27 36 131315 Valve Foot 1 328254 4 28 37 50712 Body...

Страница 6: ...15 and Nuts 16 that secure Pump Tube Assembly 4 to Cover 14 Remove the Pump Tube Assembly from the Cover 3 Unscrew the Electronic Meter from Nipple 3 4 Remove Nozzle Assembly 22 from Material Hose 24...

Страница 7: ...lunger Body Clean and Inspect NOTE Use the repair kit for replacement parts Make sure all the components are included in the kit before discarding used parts 1 Clean all metal parts in cleaning solven...

Страница 8: ...and Lever Assembly 17 Install Screw 8 that secures the Bracket and Lever Assembly to the Link 18 Install Nut 12 onto the Screw Tighten the Nut securely 19 Install the Bracket and Lever Assembly and Li...

Страница 9: ...rial Hose 24 with thread sealant as required Fluid Filter NOTE Refer to Figure 4 for component identification 32 Install Filter Tube 40 into Body 39 33 Install O Ring 42 onto Spring and Adapter Assemb...

Страница 10: ...tlet Body 28 1 Tube 35 not sufficiently tight 2 Damaged Gasket 34 1 Tighten Tube 35 into Outlet Body 28 2 Separate Tube 35 from Outlet Body 28 and replace Gasket 34 Internal Leaks Pump does not prime...

Отзывы: