Alemite 3579 Скачать руководство пользователя страница 4

SER 3579

Electronic Meter

Revision (3-10)

4

Alemite, LLC

Item No.

Part No.

Description

Quantity

1

393772-10

Guard

1

2

393772-11

Kit, Oval Gear

1

3

340162

Labels, Fluid

1

4

393772-12

Kit, Battery Cap

2

Figure 2

Electronic Meter Model 3579 - Exploded View

Troubleshooting Chart

Meter Indications

Possible Problems

Solution

Battery icon appears solid or flashes on 
display or LCD values are faded

1. Weak batteries
2. Dirty contacts

1. Replace batteries
2. Clean batteries and terminals

Meter does not measure accurately

Incorrect calibration factor

Recalibrate the meter

Display blank

Batteries installed incorrectly

Install the batteries as indicated on the bottom of 
the meter

Reduced or zero flow

1. Gears jammed
2. Clogged system

1. Overhaul metering gear cavity
2. Clean system filter

Meter does not count and the flow rate
is normal

1. Gears installed incorrectly

2. Register defective

1. Install the magnet gear (magnets upward) onto 

the left post of the body. See 

Figure

 

2

.

2. Replace meter

Err 1 flashing

Damaged register

Replace meter

Err 2 displays

Temporary lapse in data calculation

Wait until the register updates automatically

Отзывы: