![Alemite 3579 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/alemite/3579/3579_service-manual_2893746004.webp)
SER 3579
Electronic Meter
Revision (3-10)
4
Alemite, LLC
Item No.
Part No.
Description
Quantity
1
393772-10
Guard
1
2
393772-11
Kit, Oval Gear
1
3
340162
Labels, Fluid
1
4
393772-12
Kit, Battery Cap
2
Figure 2
Electronic Meter Model 3579 - Exploded View
Troubleshooting Chart
Meter Indications
Possible Problems
Solution
Battery icon appears solid or flashes on
display or LCD values are faded
1. Weak batteries
2. Dirty contacts
1. Replace batteries
2. Clean batteries and terminals
Meter does not measure accurately
Incorrect calibration factor
Recalibrate the meter
Display blank
Batteries installed incorrectly
Install the batteries as indicated on the bottom of
the meter
Reduced or zero flow
1. Gears jammed
2. Clogged system
1. Overhaul metering gear cavity
2. Clean system filter
Meter does not count and the flow rate
is normal
1. Gears installed incorrectly
2. Register defective
1. Install the magnet gear (magnets upward) onto
the left post of the body. See
Figure
2
.
2. Replace meter
Err 1 flashing
Damaged register
Replace meter
Err 2 displays
Temporary lapse in data calculation
Wait until the register updates automatically