Screen 1 

-  Limit Setup 

To go to the other menu 

-  SpO2 Hi 

Set hi levels of oxygen

  

percentage

-  SpO2 Lo 

Set low levels of oxygen 

  

percentage

-  PR Hi 

Set high levels of pulse

  

rate

-  PR Lo 

Set low levels of pulse rate

-  +/- 

Switch between going

 

 

higher or lower

-  Exit 

To exit the menu 

Screen 2 

-  Remind Setup  To go to the other menu 

-  Sound reminder  To switch the alarm on or off

-  Beep 

To switch the pulse rate

 

 

alarm on or off

-  Demo 

to play a demo (power off to 

  

start again without the demo)

-  Restore 

To restore back to factory

  

settings

-  Brightness 

To set the display intensity

-  Exit 

To exit the menu 

Maintenance: 

Cleaning and storage: 

•  The device is non-sterile and not intended to be 

sterilized. 

• 

Clean the black rubber finger sleeve before and 

after using with medicinal alcohol (> 95%).

•  The  exterior part of the tester can be cleaned 

using a damp cloth. The ACS-31 is not water-

proof, so DO NOT immerse in water. 

•  Keep the pulse Oximeter out of the reach of 

children, and preferably inside the included 

case in a dry place. 

• 

See the technical specifications regarding 

storage conditions.

Batteries:

•  The batteries can power the unit for over 20 

hours continuously.

•  If the device will not be used for a long period 

(> 2 months), remove the batteries. Doing so 

prevent any possible damage from leaking 

batteries. 

•  Replace the batteries when the battery indi-

cator shows that the batteries are running low   

(display:   or  ).

•  Always place two identical batteries, type 

alkaline, size AAA. 

•  Rechargeable batteries should not be used 

due to their lower voltage.

Environment:

• 

Should the device need to be discarded, 

hand it over to your supplier. They 

will dispose of it in an environmen-

tally friendly manner. 

•  Empty batteries can be returned to the sup-

plier or disposed of in an environmentally-

friendly manner according to your local regu-

lations. Do not dispose of used batteries with 

your normal household waste. 

Technical: 

• 

24 months Warranty ● ACS-31 does not con

-

tain any service components/accessories ● 

maintenance only through the service depart-

ment of Alecto. 

Calibration: 

•  The ACS-31 does not need to be calibrated. 

Declaration of Conformity: 

• 

http://DOC.hesdo.com/ACS-31-DOC.pdf

Specifications:

•  Display: Colour, type OLED 

•  Pulse rate:

Range: 30bpm ~ 250bpm

Resolution: 1bpm 

Accuracy: 1bpm 

Strength: bar chart  (bpm = beats per minute) 

•  SpO

2:

Range: 35 -100% 

Resolution: 1% 

Accuracy:  90% -100%: ±2%

 

70% - 90%: ±3%

 

< 70%:

 unspecified 

•  Perfusion Index

:

Range: 0-20%

Resolution: 0,1%

Accuracy:  0% - 1%: 0,1%

 

1% - 20%: 1%

•  Batteries: 2x AAA, 1.5V, Alkaline

Consumption: 30mA (nominal) 

Battery life: >20 hours continuous use 

•  Dimensions, weight: 

62,8 x 38 x 29mm / 51 grams (incl. batt)

•  Surroundings:

Operating temperature: 5°C ~ 40°C 

Storage temperature: -10°C ~ 50°C 

Operating humidity: 15% ~ 80% 

Storage Humidity: 10% ~ 93% 

: Shanghai International Holding Corp. 

GmbH (Europe).

Eiffestrasse 80, 20537, Hamburg, Germany.

: Shenzhen AEON Technology Co. LTD.

RM6H02, Block 27-29, Tianxia IC Industrial Park 

Majialong, No. 133 of Yiyuan Road, Nantou 

Street, Nanshan District, Shenzhen, China.

Model: A340