Alean SM-HWDS-Z11 Скачать руководство пользователя страница 3

1st digit

2nd digit

3rd digit

4th digit

Way of enter

Way of ex it

Normal working

condition

Enter normal working mode when no

operation or ex it operation

Debugging

alignment model

Display C

Display 0

Press the function adjustment button for

more than 3 seconds to enter the

alignment mode

Press again to ex it

when last beam is

displayed

Debugging

alignment

model(Visible light)

Display L

Display 0

Press the function adjustment button for

more than 10 seconds to enter the

alignment mode (Note: Visible light

aligner and invisible light aligner cannot

Press again to ex it

when last beam is

displayed

0000 means normal working condition

01~12 indicates the current beam.If 01 is

displayed,it means that the current aligning

beam is the 1st beam,and so on.

01~12 indicates the current beam.If 01 is

displayed,it means that the current aligning

beam is the 1st beam,and so on.

1st digit

2nd digit

3rd digit

4th digit

Way of enter

Way of ex it

Normal working

condition

Display 0

Enter normal working mode

when no operation or ex it

operation

Debugging alignment

mode

Display C

Press the function

adjustment button for more

than 3 seconds to enter the

alignment mode

Press again to ex it

when last beam is

displayed

Trigger condition

setting

Display E

Press the function

adjustment button 2 times to

enter this mode

Response time

setting

Display F

Press the function

adjustment button 3 times to

enter this mode

Bypass Laser Beam

setting

Display H

Keep pressing function

button >10seconds, and then

into bypass mode.

Detector will auto

play from 01 beam to

the last beam and

then auto ex it.

(1) 01~12: The current laser beam which need ON/OFF bypass.

After into programming, it will auto play from 01 beam to 12beams

till ex it.(2) Digit display of beam number blinking, means that

beam is bypass status.(3) Digit display of beam number keeping

lighting,means that beam is activated mode.(4) If need change

the laser beam status, just click the function button once when

auto playing the beams on the LED Digital display.

1~12 indicates the current beam. If 1 is

displayed, the beam with the lowest signal

is 1 or the current 1 beam is triggered.

0 ~ 9 indicates the

current beam signal

intensity, 9 is the

strongest signal, and

0 is the weakest

signal.

01-12 indicates the current beam. If 01 is

displayed, it means that the current

aligning beam is the first beam, and so on

001~012 indicate the current trigger conditions. If 001 is

displayed, it means that the current trigger condition is to block 1

beam to trigger the alarm, and so on. If the current display is 003

when setting, it means that the current trigger condition is to

block 3 beams to trigger the alarm.

Automatically save

and ex it after 5

seconds without any

operation, return to

normal working

mode

050, 100, 300, and 700 indicate that the alarm response time is

50ms, 100ms, 300ms and 700ms. If 50 is displayed, the trigger

response time is currently set to 50ms, and so on.