ALDI AU4-PU-4 Скачать руководство пользователя страница 20

 

Heart Rate Monitor 

Main functional modes

 

 

AFTER SALES SUPPORT   

 

service@produktservice.info / www.produktservice.info    

 

1-800-493-9137

 

20 

Stopwatch (in heart rate mode): 

 

Measurement range:  99 hours 59 minutes 59 seconds  

 

Resolution:   

1/100 second 

Countdown: 

 

Measurement range:  9 hours 59 minutes 

 

Resolution:   

1 second 

Heart rate: 

 

Measurement range:  30 to 240 bpm (beats/minute) 

 

Resolution:   

1 bpm 

Calories 

 

Measurement range:  0 to 99,999 kcal  

 

Resolution:   

0.01 to 999.99 kcal 

 

 

 

above 0.1 / 1  

Fat 

 

Measurement range:  0 to 99,999 g  

 

Resolution:   

0.01 to 999.99 g 

 

 

 

above 0.1 / 1  

 

  Battery Change 

5.9

 

Caution!

  Risk of explosion with improper replacement of the battery. Replacement 

only with the same or equivalent type of battery.  

 

For battery replacement, proceed as follows: 

 

Using a small, crosshead screwdriver, unscrew the four 
screws on the cover at the back of the heart rate monitor 
and remove them. 

 

Then, open the battery holder by carefully lifting the locking 
bracket over the locking hook using the screwdriver.  

 

Remove the depleted battery and dispose of it properly 
and environmentally.  

 

Insert a new 3V battery type CR2032 with the positive 
terminal (+) upwards into the holder and push it until it locks in. Ensure that you 
pay attention to the correct polarity.  

 

Place the back cover back onto the battery compartment. When doing so, 
ensure that the rubber seal of the watch is not shifted or damaged. Screw the 
cover back on with the four screws.  

 

Start the watch as described in point 5 “Main functional modes”. 

 

If irregular symbols should appear in the display, remove the battery again and 
reinsert it. This will reset the microprocessor. After this,  the heart rate monitor 
should function normally again. 

Note:

 Please note that after a battery replacement, all personal data needs to be re-

entered. 

Содержание AU4-PU-4

Страница 1: ...Heart Rate Monitor User Manual...

Страница 2: ...A 4B 4C 4D Type HRM F68 BA Incl 1 x 3 V CR2032 battery lithium button cell already inserted 1 chest strap Model no AU4 PU 4 Type TH S4 LF Incl 1 x 3 V CR2032 battery lithium button cell already insert...

Страница 3: ...commercial purposes The heart rate monitor is not a medical device Please read these operating instructions in order to familiarise yourself with all of the options for your heart rate monitor and en...

Страница 4: ...children Batteries can be swallowed by children Seek immediate medical attention if this happens Avoid contact with skin eyes and mucous membrane if leakage occurs Upon contact with battery acid rins...

Страница 5: ...tch specialist in order to avoid damage to the seal ring and housing Disposal 2 4 Dispose of the packaging in the proper manner Batteries need to be properly disposed of For this purpose shops selling...

Страница 6: ...product service page for further help with your heart rate monitor http www produktservice info EAN Code 20015152 3 FUNCTION KEYS OF THE HEART RATE MONITOR 4 START UP BEFORE STARTING Function keys of...

Страница 7: ...In the Basic mode only the heart rate mode is available with the display of the stop watch The MODE and SEL key do not work in this mode In the Normal mode only the time mode and the heart rate mode...

Страница 8: ...the following order Language English German 12 24 hour display 12 24 Set the time and date Date of birth year month day If you were born prior to 1950 simply increase the year beyond 2011 and the cou...

Страница 9: ...2 Press the MODE key repeatedly until you are in the time mode displayed by ZEIT TIME In time mode the day of the week and date are shown in the top display segment the hours and minutes in the middl...

Страница 10: ...by PULS PULSE In heart rate mode the time is shown in the top display segment the current heart rate in the middle segment and the of maximum heart rate in the bottom segment The maximum heart rate is...

Страница 11: ...5 3 1 Stopwatch The stopwatch in the heart rate mode has the function of a training timer In heart rate mode press the SEL key until the stopwatch STOPP STW is displayed in the top display segment Wh...

Страница 12: ...ime during which you were below the selected training zone UNTER BELOW In order to reset these values to zero please keep the SET key in the stopwatch view pressed for approx 3 seconds The total train...

Страница 13: ...er and lower limits of the three specified training zones Zone 1 50 65 of MHR Zone 2 65 80 of MHR Zone 3 80 95 of MHR Different training zones Depending on which goal you are pursuing with your traini...

Страница 14: ...65 of your maximum heart rate as the lower limit Zone 2 Example Upper limit 80 188 x 0 8 150 Lower limit 65 188 x 0 65 122 5 3 4 a Setting the alarm type the maximum heart rate and the training zones...

Страница 15: ...of the heart frequency or with an irregular heart under certain circumstances it can occur that the LED indicator and the training zone alarm will temporarily stop in order to avoid incorrect informa...

Страница 16: ...in order to start a 5 minute countdown After the countdown recovery phase your heart rate and fitness level will be displayed Fitness level Heart rate after 5 min Level 6 130 Level 5 130 120 Level 4 1...

Страница 17: ...rder to obtain a meaningful value for calorie consumption and fat burning it is necessary to enter the date of birth and weight correctly Note The body fat function is only active when the heart rate...

Страница 18: ...to set the hours Confirm your selection with the SET key the minutes will flash Set the minutes with the SEL key Now press the MODE key all settings are saved Use countdown Press SET key Start countdo...

Страница 19: ...m mode but also in time mode Switch off alarm When the alarm sounds you can switch it off by pressing the MODE SEL SET or LIGHT key Display light 5 7 By pressing the LIGHT key the display is illuminat...

Страница 20: ...the four screws on the cover at the back of the heart rate monitor and remove them Then open the battery holder by carefully lifting the locking bracket over the locking hook using the screwdriver Re...

Страница 21: ...o radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh...

Страница 22: ...high voltage lines above ground and underground overhead cables electric motors car motors mobile phones aircraft etc Battery in chest strap too weak please replace Distance to the chest strap is too...

Страница 23: ...correct polarity If the battery needs to be removed and reinserted the personal data will need to be re entered Why is the display light not working Is the battery perhaps depleted Please check the ba...

Отзывы: