(120VAC Bare Lead Model - full product)
1. DISCONNECT ALL ELECTRICAL SERVICE BEFORE WORKING ON OR HANDLING THE PRODUCT.
2. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE,
ETC. DO NOT USE IN EXPLOSIVE ATMOSPHERES.
3. PROBEX™ PUMP SWITCH MUST ONLY BE USED WITH PUMPS CONTAINING INTEGRAL THERMAL
MOTOR OVERLOAD PROTECTION.
Safety Guidelines
Before proceeding with the installation or operation of the product, make sure
to read all instructions thoroughly, as well as complying with all Federal, State
and Local Codes, Regulations and Practices. The product must be installed by
qualified personnel familiar with all applicable local electrical and mechanical
codes. Refer to the National Electrical Code (NFPA 70). Failure to properly install
and test this product can result in personal injury or equipment malfunction.
Introduction
PUMP
DO NOT
Install in
the Water Reservoir
MUST
Install the ProbeX™ Housing/Enclosure
OUTSIDE
of the Reservoir
Allowable to install
ONLY THE PROBES
in a pond or water feature
where humans or animals can contact the water
120VAC Model
(pump switch housing/enclosure only)
ProbeX™ Probes
(Reference, Stop/Red, and Start/Green)
Line Voltage
Low Voltage
Submersible
Pump
Allowable to install ProbeX™ in
a tank with a Submersible Pump
WARNING!
Do not allow the ProbeX™ pump switch housing/enclosure and power cable to be submerged in ponds or other environments that can be a shock
hazard to humans or animals. The probes however, are low voltage (12VDC), and can be in the water if the ProbeX™ housing/enclosure is mounted out of the
water. For applications where a submersible pump is used, the ProbeX™ is completely waterproof and can be submerged in the same tank.
Alderon Industries • PO Box 827 Hawley, MN 56549 • P: 218-483-3034 • F: 218-483-3036 • alderonind.com
Installation Instructions | Page 1
QSG00118_Rev02_IOM000022B ProbeX Pump Switch | September 23, 2020 6:43 AM
Operation, Maintenance and Installation Manual
ProbeX™ Series Vertical Pump Switch
ProbeX
™
Pump Switch