NB.
* The symbol for the function is displayed in the control panel only when
an optional card is installed.
** The product must be installed and activated for this function to be
available.
Night mode
Save gas and electric while you sleep by lowering the
temperature and shutting off the hot water.
Day mode
This function is used to automatically change certain
functions, e.g. if you are away for a while during the day.
Priority setting
Select what type of energy – gas or electricity – is to be
prioritised.
Brightness
Adjust the brightness in the display in working mode in
three steps and backlighting in stand-by mode can be
set in three different modes, for example, dark if you
want to completely turn off the display’s backlighting
at night.
Settings, room sensors
* **
If multiple room sensors are installed, you can choose
which sensor is to be active, e.g. the living quarters, the
sleeping quarters or the panel.
Clock
The clock shows the day and time, and has to be set if
you want to use the automatic temperature change or
automatic start function.
Antibacterial Mode
(legionella)
The boiler starts at 02:00 daily and operates at max-
imum temperature for 30 minutes to reduce the risk
of legionella.
Offset
If the temperature that is displayed in the panel does
not correspond to the actual temperature, it can be
adjusted by ±5°C in the panel. Applies also to display
of external temperature.
High altitude mode
The function should only be used if the boiler will be
powered by LPG at a height above 1000 m above sea
level.
Sound
Audible signals in various situations, e.g. button
sound, hot water temperature and gas Failure.
Automatic start
For automatic starting of the boiler at a selected time
on a selected day.
Pump settings
Selection of circulation pump and operating mode
which can be set for constant operation or controlled
Reset
Resetting the system to factory settings.
External start
*
Used when starting the boiler externally, e.g. using
GSM** or 230 V.
Language
Used to switch the display to different languages
(English, French and German).
Activation of installed functions
The first time you use the heating system,
check that the right accessories/functions
are activated. This also applies when you
supplement the heating system with acces-
sories/functions.
Settings 1
Settings 3
Settings 4
Settings 2
EisEX, 12 V defroster
* **
Activates a heating element which prevents ice forming
in the regulator in winter.
Overload protection
* **
Prevents overloading the 230 V fuses.
If the total current consumption exceeds a set value, the
boiler output is reduced automatically.
Booster
* **
Controls the speed and fan start/stop in the heat boost-
er.
Pump, underfloor heating
* **
The underfloor heating pump is operational at the same
time as the heating system’s main pump starts.
Pump, engine heating
* **
Activates the circulation pump on the engine circuit for
the camper van. The heating system then operates as
an engine heater and heats up the coolant in the engine
via a heat exchanger.
Settings Menu