![Alcor AU9510 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/alcor/au9510/au9510_technical-reference-manual_2892660019.webp)
ELECTRICAL
CHARACTERISTICS
15
6.0 Electrical Characteristics
6.1. Absolute Maximum Ratings
SYMBOL
PARAMETER
RATING
UNITS
V
CC
Power Supply
-0.3 to 6.0
V
V
IN
Input Voltage
-0.3 to VCC+0.3
V
V
OUT
Output Voltage
-0.3 to VCC+0.3
V
T
STG
Storage Temperature
-40 to 125
˚
C
6.2. Recommended Operating Conditions
SYMBOL
PARAMETER
MIN
TYP
MAX
UNITS
V
CC
Power
Supply
4.5
5.0
5.5
V
V
IN
Input
Voltage
0
V
CC
V
T
OPR
Operating
Temperature
-5 85
O
C
6.3. General DC Characteristics
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP MAX UNITS
I
IL
Input low current
no pull-up or pull-down
-1
1
µ
A
I
IH
Input high current
no pull-up or pull-down
-1
1
µ
A
I
OZ
Tri-state leakage current
-10
10
µ
A
C
IN
Input
capacitance
4
ρ
F
C
OUT
Output
capacitance
4
ρ
F
C
BID
Bi-directional buffer capacitance
4
ρ
F
Содержание AU9510
Страница 4: ...TABLE OF CONTENTS i...
Страница 6: ...INTRODUCTION 2 This Page Intentionally Left Blank...
Страница 8: ...APPLICATION BLOCK DIAGRAM 4 This Page Intentionally Left Blank...
Страница 12: ...PIN ASSIGNMENT 8 This Page Intentionally Left Blank...
Страница 18: ...PROGRAMMING INTERFACE 14 This Page Intentionally Left Blank...
Страница 24: ...ELECTRICAL CHARACTERISTICS 20...
Страница 28: ...ELECTRICAL CHARACTERISTICS 24 This page Intentionally Left Blank...