![Alcor AU9310 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/alcor/au9310/au9310_technical-reference-manual_2892656019.webp)
ELECTRICAL
CHARACTERISTICS
15
5.5 ESD Test Results
Test Description
: ESD Testing was performed on a Zapmaster system using the Human-
Body –Model (HBM) and Machine-Model (MM), according to MIL_STD 883 and EIAJ
IC_121 respectively.
Human-Body-Model stress devices by sudden application of a high voltage supplied
by a 100 PF capacitor through 1.5 Kohm resistance.
Machine-Model stresses devices by sudden application of a high voltage supplied by a
200 PF capacitor through very low (0 ohm) resistance
Test circuit & condition
Zap Interval : 1 second
Number of Zaps : 3 positive and 3 negative at room temperature
Critera : I-V Curve Tracing
Model Model
S/S
TARGET Results
HBM
Vdd, Vss, I/C
15
4000V
Pass
MM
Vdd, Vss, I/C
15
200V
Pass
Содержание AU9310
Страница 4: ...TABLE OF CONTENTS i This page Intentionally Left Blank...
Страница 6: ...INTRODUCTION 2 This Page Intentionally Left Blank...
Страница 8: ...APPLICATION BLOCK DIAGRAM 4 This Page Intentionally Left Blank...
Страница 16: ...SYSTEM ARCHITECTURE AND REFERENCE DESIGN 12 This Page Intentionally Left Blank...
Страница 22: ...ELECTRICAL CHARACTERISTICS 18 This Page Intentionally Left Blank...