Please read the user's manual carefully before use.

AF-50

AF-50

Breath Alcohol Tester

Professional Fuel cell sensor
Personal & professional use alcohol tester

Instruction

Manual

50 sets of data memory 
Professional Fuel Cell Sensor
Law enforcement grade accuracy
4-digit LCD display with a backlit
Fast analyzing and result
Automatic power off
User adjustable settings 
(Blow time, Unit, Beep alarm, 
Blow detecting)

Содержание AF-50

Страница 1: ... cell sensor Personal professional use alcohol tester Instruction Manual 50 sets of data memory Professional Fuel Cell Sensor Law enforcement grade accuracy 4 digit LCD display with a backlit Fast analyzing and result Automatic power off User adjustable settings Blow time Unit Beep alarm Blow detecting ...

Страница 2: ...ve The manufacturer and the sellers will not take any legal responsibility for the test results When not used for a long time keep the device after taking out the batteries In case of testing after long term storage there might be high tolerance of test results for the first 3 tests Replace the batteries when the battery indicator icon reaches empty for the accuracy reason In case the test result ...

Страница 3: ...ower button The total number of test performed will be displayed briefly and start countdown When the countdown reaches zero with a double beep sound three dashes will be displayed and START will flash Take a deep breath and blow the mouthpiece for five seconds until there is a double beep sound Digital Breathalyzer ALCOFIND AF 50 Two AAsize Batteries 6 six Mouthpieces Carrying Case User s Manual ...

Страница 4: ...arm at 0 05 BAC the tester will sound an audible warning alarm when the test result is over 0 05 BAC If user set none the tester will not sound at all Recommended to set the value at your country s BAC Limit Adjust blow time When bL t appears on the display press the start button to adjust the blow time A longer blow time may provide a deep lung air which may provide more accurate reading Adjust f...

Страница 5: ...lown within 30 seconds the LCD will display OUT If the unit is powered on beyond the acceptable temperature range the unit will display it 5 40 C or 41 104 F Full battery Technical specifications Indication of B A C Accuracy Warm up time Sensor Power supply Battery Life Dimensions WxHxD Weight Calibration Operating temperature 0 000 0 500 BAC 0 00 5 00 0 00 2 50mg l 0 005 BAC at 0 1 BAC at 25 C 0 ...

Страница 6: ...bration under normal use either for 1 one year from the date of purchase or 500 breath tests whichever comes earlier The manufacturer s obligation under this warranty is limited to replacing adjusting or repairing the unit at manufacturer s option if returned along with proof of purchase For any defects due to natural disaster or customer s negligence misuse reconstruction and repair by unauthoriz...