Setting the digital display

The AIR 160 can be set using the display on the front of the 
device. The display can be easily operated with just the one button. 

Drawing 7

 of these instructions for use shows how to navigate 

through the menu. Details on each setting can be found below.

After the start-up, the validity of the time will be tested first. 
When you switch the device on for the first time, the software 
will automatically take you to the ‘clock set mode’. You can set the 
current time here.

You can set the hours by pressing the button briefly. The time is 
displayed in a 24-hour format. After the hours have been correctly 
set, you can jump to the minute setting by pressing the button for 
3 seconds. You can now set the minutes by briefly pressing the
button as many times as necessary. As soon as the time has been 
correctly set, wait 5 seconds. The software will automatically save 
the time, and the dot next to the second digit will blink every 
second.

‘8000.’: 

If you press the button once in the rest position, the 

operating hours will be displayed. The display will automatically 
start from the factory setting of the timer, i.e. 8,000 hours. 
The UV-C lamp operates at 100% radiation for up to 8,000 hours. 
After 8,000 operating hours, the UV-C radiation will weaken, and 
may be insufficient to obtain the desired results. If the device 
is switched off and then on again, the hour counter will start 
counting backwards from the value it had when it was switched off.

‘t-LO’: 

If you press the button twice in the rest position, the 

indication ‘t-LO’ will appear. This means: The low position of the air 
circulation. The ventilator is hereby set
for an air circulation of 25 m3 per hour, and the device is virtually 
silent. The low air circulation can be set by pressing and holding the 
button for 3 seconds while the ‘t-LO’ indication is visible on the 
display. When the hour digits start blinking, you can set the
hour at which the device should switch to the low position. The 
hours will start counting upwards as soon as the button is pressed. 
You can set the desired hour by briefly pressing the button again. 
The minutes will start blinking 5 seconds after you
have released the button, and you can then set the minutes. The 
settings will be saved, and the current time will be displayed after 5 
seconds.

‘t-HI’: 

The ‘t-HI’ indication will appear if you press the button 

three times in the rest position. This means: The high position of 
the air circulation. The ventilator hereby is set for an air circulation 
of 50 m3 per hour. The high air circulation can be set by pressing 
and holding the button for 3 seconds when the indication ‘t-HI’ is 
visible on the display. When the digits for the hours start blinking, 
you can set the hour at which the device should switch to the 
high position. The hours will start counting upwards as soon as the 
button is pressed. You can set the desired hour by briefly pressing 
the button again. The minutes will start blinking 5 seconds after you 
have released the button, and you can then set the minutes. The 
settings will be saved, and the current time will be displayed after  
5 seconds.

‘SEt’: 

The ‘SEt’ indication will appear if you press the button four 

times in the rest position. This means: Set clock. The real time 
clock is hereby set. The clock can be set by pressing and holding 
the button for 3 seconds when the ‘SEt’ indication is visible on the 
display. You can set the hours when the digits for the hours start 
blinking. The hours will start counting upwards as soon as the 
button is pressed. You can set the desired hour by briefly pressing 

the button again. The minutes will start blinking 5 seconds after you 
have released the button, and you can then set the minutes. The 
settings will be saved, and the current time will be displayed after 
5 seconds.

‘rSt’: 

The ‘rSt’ indication will appear if you press the button five 

times in the rest position. This means: Reset. This option is used 
to reset the timer. After you have replaced the lamp and the filter, 
you can reset the timer to 8,000 hours. The timer can be reset 
to 8,000 hours by pressing and holding the button for 3 seconds 
while the ‘rSt’ indication is visible on the display. The settings will be 
saved, and the current time will be displayed after 5 seconds.

‘0000.’

: The display will indicate 0000 when the 8,000 operating 

hours of the lamp have expired. The actual time will blink in the 
display, alternating with four blinking zeros. The filter and the UV-C 
lamp must now be replaced. See item ‘rSt’ for resetting
the timer.

‘FAIL’: 

The software stops if there is a problem with the real time 

clock or with the ventilator connection. As soon as the device is 
switched on, the program will carry out a self-test to check the 
proper operation of the product. The units that are checked are
the real time clock and the ventilator connection. Any problems 
with these items will be indicated on the display.

Switching off the display illumination

The display illumination can be switched off by pressing and 
holding down the display button for 10 seconds. This will not 
switch the device off, and the settings will be retained. The display 
illumination is switched on again by briefly pressing the display
button once.

Switching off the device

It is not necessary to switch off the device during the day because 
it has been designed to operate 24 hours a day to avoid the 
formation of new micro-organisms. You can switch the device off 
by removing the plug from the socket.

Dismantling / Maintenance

During maintenance work, or when dismantling the device, always 
switch off the power supply by removing the plug from the socket. 
The device must be cleaned at least once a year. 

If dust deposits on the filter more quickly, the filter should be 

replaced more than once a year. The special lamp must be replaced 

after 8,000 operating hours at the latest. Clean the aluminium 

interior with a soft cloth.

1.  

Unscrew the AIR 160 + cover the clips (see Drawing 4) open

and remove the AIR 160 from the clips

 (A)

.

2.  Using a screwdriver, unscrew the 2 screws 

(B)

 from the filter

grid 

(C)

 on the underside of the device.

3.  Loosen the filter grid 

(C)

 and remove the filter 

(E)

 from the

filter holder 

(D)

.

4.  Carefully pull the UV-C lamp 

(F)

 from the lamp fitting 

(H)

, then

turn it by a quarter-turn to enable you to easily remove the

UV-C lamp 

(F)

 from the lamp clip 

(G)

 of the device. 

5.  Clean the interior of the aluminium housing 

(L) 

with a soft cloth.

6.  Carefully insert the (new) UV-C lamp 

(F)

 into the lamp clip 

(G)

in a vertical position, pushing the UV-C lamp 

(F)

 through until it

almost reaches the lamp fitting 

(H)

. Turn the lamp by a quarter-

turn to fix it more tightly into the lamp clip 

(G)

, and then

carefully push the lamp into the lamp fitting 

(H)

 (see Drawing 6).