Page
| 5
Alchemi Supercharger™ User Manual
Shutdown
1)
The charger will enter sleep mode if inactive for 4
hours. The red status LED will flash periodically. Press
the pushbutton knob for 2 seconds to wake the unit.
2)
To disconnect the unit, first ensure the unit is not
charging by pressing and holding the pushbutton
knob. Ensure that the green Charging LED is off.
3)
Disconnect the AC mains cable and the DC cable in
this order. The unit will turn off.
3.
Battery Profile Selection
Incorrect battery charging is the largest
preventable cause of premature battery failure.
Please see the Alchemi website for list of standard
charge algorithms and for more information.
The Alchemi A.I. charge algorithm is divided into
up to 5 phase sequences to put energy into the
battery correctly. Each phase can be terminated
by 1) voltage,2) current, or 3) a fixed duration. Every
phase has a variable timer to prevent “stuck”
phases where the charger does not shutdown.
An example 5-step rapid-charge Lithium profile is
demonstrated below using the Alchemi A.I. charge
algorithm.