B-3
Fiber Standards
B
tests are specified in the ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional
Transmission Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”
Note that when testing your cable installation, be sure to include all patch cables
between switches and end devices.
Adjusting Existing Category 5 Cabling to Run 1000BASE-T
If your existing Category 5 installation does not meet one of the test parameters for
1000BASE-T, there are basically three measures that can be applied to try and
correct the problem:
1.
Replace any Category 5 patch cables with high-performance Category 5e or
Category 6 cables.
2.
Reduce the number of connectors used in the link.
3.
Reconnect some of the connectors in the link.
Fiber Standards
The current TIA (Telecommunications Industry Association) 568-A specification on
optical fiber cabling consists of one recognized cable type for horizontal subsytems
and two cable types for backbone subsystems
.
Horizontal
62.5/125 micron multimode (two fibers per outlet).
Backbone
62.5/125 micron multimode or singlemode.
TIA 568-B will allow the use of 50/125 micron multimode optical fiber in both the
horizontal and backbone in addition to the types listed above. All optical fiber
components and installation practices must meet applicable building and safety
codes.
Содержание OmniStack 6300-24
Страница 1: ...Part No 060190 10 Rev A December 2003 OmniStack 6300 24 Getting Started Guide...
Страница 4: ......
Страница 14: ...xii Tables...
Страница 16: ...xiv Figures...
Страница 36: ...3 8 Installing the Switch 3...
Страница 48: ...B 4 Cables B...
Страница 54: ...Glossary Glossary 4...
Страница 57: ......
Страница 58: ...060190 10...