23 — Cross-connecting circuits
2902 MainStreet Technical Practices
23-5
May 2002 90-2906-01
23.4
Circuit connections display
You can view a display of a single circuit connection or a group of connections.
Figure 23-2 is an example of the SHOW_GROUP display, showing a simple RS-232
DCM circuit connection (P1-01 to M01-1) and a V.35 DCM super-rate
cross-connection (P1-05 through P1-08 to M05-01).
Current connections are indicated by an asterisk.
Procedure 23-3 To display circuit connections
CONFIG — CONNECT — <
pp-c
> or <P
p-c
>
↵
— SHOW_CCT*/SHOW_GROUP
where
pp
is 1 or 9,
p
is 1 or 2, and
c
is 1 to 30 (for primary rate), or 1, 2, A or B (for interface
module)
* Default
Figure 23-2 Circuit connections display
23.5
Protecting connections (RAPID protection switching)
The 2902 MainStreet NTU provides RAPID circuit protection. You can protect a
connection by specifying an alternate connection in case of a circuit or link failure.
The original connection is called the preferred connection and the alternate
connection is the protecting connection.
2902 MainStreet 82211-ab-cd OSLO Alarms:2 09-JAN-1997 10:19A
Circuit Name Type Circuit Name Type
P1-01 *E1_RS232_DCM M01-01 RS232_DCM
P1-02 E1_SIG ---
P1-03 E1_SIG ---
P1-04 E1_SIG ---
P1-05 *E1_V35_DCM M05-01 V35_DCM
P1-06 *E1_V35_DCM M05-01 V35_DCM
P1-07 *E1_V35_DCM M05-01 V35_DCM
P1-08 *E1_V35_DCM M05-01 V35_DCM
P1-09 E1_SIG ---
P1-10 E1_SIG ---
P1-11 E1_SIG ---
P1-12 E1_SIG ---
Asterisks indicate current connections
CONFIG CONNECT P1-1
1-SHOW_CCT 2-DISCONNECT 3-TO_CIRCUIT 4- 5-
6- 7- 8-CANCEL 9-QUIT 0-
Содержание MainStreet 2902
Страница 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Страница 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 168: ...16 E1 circuit operating parameters 16 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Страница 343: ......
Страница 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...