Alcatel Vacuum Technology France --- IPUP A100 Instruction manual
Use of the serial link
MODIFYING THE HEADER
CHARACTER
ORDER
PARAMETER
RESPONSE
ACTION
HDR
<val>
val = decimal
value of the
ASCII code of
the header
character
between 0
and 127.
OK
or
ERR3
l
Change the header character
in front of a response address.
l
The factory configuration is the
decimal code ”035” of the cha-
racter ”#”.
l
Memorization of the customer
configuration by the monitoring.
l
The code ”000” corresponds to
”no header character”.
Example :
The value ”047”, the decimal ASCII code of the character ”
/
”.
command
#002HDR047<CR>
response
/002OK
command
002IDN<CR>
response
/002M4ADP100X V1.XX
INTERPRETING RESPONSES
SUPPLIED BY THE SERIAL LINK
OK or a specific response to the order if everything is correct.
ERR0 : setting fault
ERR1 : order fault
ERR2 : parameter fault
ERR3 : context fault
ERR4 : checksum fault
NOTE
: ”The remote control mode” has priority on RS 232 or RS 485
commands.