4-4
4.5
TURN-ON PROCEDURE
For user safety, user should become familiar with locations of power
distribution units and circuit breakers associated with the MDR-8000
radio.
Perform the following procedure to turn on the radio.
A.
On power supply module, set
PA ON/OFF
switch to
OFF
. Yellow
PA OFF
indicator will light.
B.
On power supply module, set
POWER ON 1/OFF 0
switch to
ON 1
.
C.
On power supply module, set
PA ON/OFF
switch to
ON
. Yellow
PA OFF
indicator will turn off.
Until both the local and farend radios in the hop are turned on and
operating properly and the RF path has been established, alarm condi-
tions will exist.
D.
Observe CHAN ALM indicator on RCVR module is lit.
E.
Wait for RCVR to lock on frequency. When RCVR is locked on frequency
(approximately 5 to 30 seconds), CHAN ALM indicator on RCVR module will
turn off.
F.
Verify all front panel alarm indicators on radio shelf are off. If not, refer to
Maintenance section for troubleshooting.
4.6
ESTABLISH COM PORT
Establish communication between the USI computer and the controller in the radio.
Disable infrared option on laptop (if equipped) to prevent disrupting
communication on com port.
A.
Connect RS-232 interface cable between USI connector on controller and PC.
See Figure 4
B.
On Windows desktop, click on
Start
icon. Program menu displays.
Only one COM port can be used at a time.
Note
Note
Note
Note