DS3/EC1 and TMUX testing procedure
Installation tests
4 - 2 2
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
DS3/EC1 and TMUX testing procedure
Description
Perform the following steps for all 1665 DMX shelf Function Unit slots containing
12DS3/EC1 (LNW16), 48DS3/EC1 (LNW19/LNW19B), 12TMUX (LNW18) and
48TMUX (LNW20) circuit packs and cabled to a DSX-3 via DS3/EC1 cabling. The
48DS3/EC1 and 48TMUX circuit packs can only be used with high capacity shelves.
If the 1665 DMX is cabled to some other type of DS3/EC1 terminating equipment, use
this procedure by substituting these ports for the DSX-3 ports called out in the procedure.
If the 1665 DMX shelf is not fully populated, it may be necessary to move the circuit
pack(s) from slot to slot in order to test all DS3/EC1 and TMUX cabling.
This procedure requires the use of a DS3 test set.
Important!
The LNW16 and LNW19/LNW19B circuit packs are provisioned on a
“per port” basis for DS3 or EC1. The default setting for all ports is DS3. Tests in the
section will verify proper cabling by using a DS3 test set with all ports provisioned as
DS3.
TMUX is only provisionable for DS3.
Verify provisioning
Verify that all ports are provisioned as DS3.
........................................................................................................................................................................................................................
1
Select View -> Equipment...
........................................................................................................................................................................................................................
2
Click on the + sign next to the CP fn with the DS3/EC1 circuit pack.
........................................................................................................................................................................................................................
3
Verify that all ports are labeled as DS3.
........................................................................................................................................................................................................................
4
To change provisioning from EC1 to DS3, select Configuration -> Equipment... Select the
DS3/EC1 circuit pack and port, then choose DS3 and click Apply.
........................................................................................................................................................................................................................
5
for each Function Group equipped with LNW16 or
LNW19/LNW19B circuit pack(s).
Содержание Data Multiplexer Explore 1665
Страница 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Страница 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Страница 168: ... 1665 Data Multiplexer 1665 DMX stand alone installation tests I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 250: ... Additional optical tests optional Installation tests 4 6 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 274: ... 1665 Data Multiplexer 1665 DMX ring setup and testing I I I 2 365 372 304R7 1 Issue 1 November 2007 ...
Страница 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Страница 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...