Declaration of compliance
8AL90386ENABed01
75 /76
12
Declaration of compliance
This equipment uses DECT frequency range that depends on country: 1880 - 1900 MHz in Europe, 1920 -
1930 MHz in US/Canada, 1910 - 1930 MHz in LATAM, 1910 - 1920 MHz in Brazil. The equivalent
isotropically radiated power at the antenna is less than 110 mW or 250 mW (it depends on the country).
EUROPE
This equipment is in compliance with the essential requirements and other relevant provisions of following
Directives: 2014/53/EU (RED), 2011/65/EU and (EU)2015/863 (RoHS).
Declaration of Conformity may be obtained from:
ALE International 32 avenue Kléber
– 92700 Colombes, France
USA and Canada
Handset complies with Part 15 of the FCC Rules, with Innovation, Science and Economic Development
Canada's licence-exempt RSS, with Part 68 of the FCC Rules and with IC CS-03 Part V of Industry Canada
(FCC ID: T7HCT8234 IC ID: 4979BCT8234). The ACTA registration number is: T7HW4NANCT8234.
Chargers comply with Part 15 of the FCC Rules and with ICES-003 of Industry Canada
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Exposure to Radio Frequency Signals
This device has been designed and manufactured not to exceed the SAR (Specific Absorption Rate) radio
frequency power transmission limits established by the different countries concerned.
For Europe/Australia:
o
8254 DECT Handset: the SAR value measured is equal to 0.05 W/kg (head SAR) / 0.05 W/kg (body
SAR) (the globally accepted maximum limit being 2 W/kg over 10g).
o
8234 DECT Handset: the SAR value measured is equal to 0.035 W/kg (head SAR) / 0.024 W/kg
(body SAR) (the globally accepted maximum limit being 2 W/kg over 10g).
For US/Canada:
o
8254 DECT Handset: the SAR value measured is equal to 0.05 W/kg (head SAR) 0.05 W/kg (body
SAR) (the globally accepted maximum limit being 1.6 W/kg over 1g).
o
8234 DECT Handset: the SAR value measured is equal to 0.04 W/kg (head SAR) / 0.02 W/kg (body
SAR) (the globally accepted maximum limit being 1.6 W/kg over 1g).
User Instructions
Only use the handset in temperatures between -15°C to +55°C (5°F to 131°F). Do not charge a battery
when the ambient room temperature is above 40º C or below 5º C (above 104º F or below 41 ºF). This
apparatus is Hearing Aid Compatible (HAC).
Acoustic shock protection
Maximum sound pressure level for handset is compliant with European, US and Australian standards.
Directive 2003/10/EC specifying the risks inherent in noise at work
The ring contributes towards overall daily noise. To reduce the level, the following is recommended: reduce
the setting, program a progressive ring.
Disposal
The equipment must be returned to a collection point for electronic equipment waste
disposal.
Defective batteries must be returned to a collection point for chemical waste disposal.
Related Documentation
other languages for these Safety and Regulatory Instructions and User Documentation are
available at the following Web site: https://www.al-enterprise.com/products.