Interface Configuration
7750 SR OS Interface Configuration Guide
Page 203
General Port Commands
port
Syntax
port
{
port-id
|
bundle-id
|
aps-id
|
bpgrp-id
}
no port
{
bundle-id
|
aps-id
|
bpgrp-id
}
Context
config
Description
This command enables access to the context to configure ports, multilink bundles, and bundle
protection groups (BPGs). Before a port can be configured, the chassis slot must be provisioned with
a valid card type and the MDA parameter must be provisioned with a valid MDA type. (See
and
commands.)
Default
No ports are configured. All ports must be explicitly configured and enabled.
Parameters
port-id —
Specifies the physical port ID in the
slot/mda/port
format.
bundle-id —
Specifies the multilink bundle to be associated with this IP interface. The command syn-
tax must be configured as follows:
Syntax
: bundle-
type
-
slot/mda.bundle-num
bundle
-
ppp
-
slot/mda.bundle-num
(Creates a multilink PPP bundle.)
bundle
-
ima
-
slot/mda.bundle-num
(Creates an IMA bundle.)
bundle
: keyword
slot
:
IOM/MDA slot numbers
bundle-num
:
1 — 256
For example:
router1>config# port bundle-ppp-5/1.1 (multilink PPP bundle)
router1>config# port bundle-ima-5/1.2 (IMA bundle)
aps-id —
This option configures APS on un-bundled SONET/SDH ports. All SONET-SDH port
parameters, with certain exceptions, for the working and protection circuit ports must be
configured in the
config>port>aps-
group-id
context. The working and protection circuit ports
inherit all those parameters configured. The exception parameters for the working and protect
circuits can be configured in the
config>port>sonet-sdh
context. Exception list commands
include:
clock-source
[no] loopback
[no] report-alarm
section-trace
[no] threshold
When an
aps-
group-id
is created all applicable parameters under the port CLI tree (including
parameters under any submenus) assume
aps-
group-id
defaults, or when those are not explicitly
specified, default to SONET/SDH port defaults for any SONET port.
.All but a few exception SONET/SDH parameters for the working channel port must be
configured in the
config>port>aps>sonet-sdh
context. The protection channel inherits all the
Содержание 7750 SR OS
Страница 6: ...Page 6 7750 SR OS Interface Configuration Guide Table of Contents ...
Страница 8: ...Page 8 7750 SR OS Interface Configuration Guide List of Tables ...
Страница 10: ...Page 10 7750 SR OS Interface Configuration Guide List of Figures ...
Страница 14: ...Preface Page 14 7750 SR OS Interface Configuration Guide ...
Страница 16: ...Getting Started Page 16 7750 SR OS Interface Configuration Guide ...
Страница 184: ...Card MDA and Port Command Reference Page 184 7750 SR OS Interface Configuration Guide ...
Страница 417: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 417 4 5 SAP PVT 1 1 up up A ima2 ...
Страница 429: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 429 Cells 0 0 Unknown VPI VCI Cells 0 A ALA 49 ...
Страница 437: ...Interface Configuration 7750 SR OS Interface Configuration Guide Page 437 bundle num 1 256 type ppp ...
Страница 438: ...Debug Commands Page 438 7750 SR OS Interface Configuration Guide ...
Страница 444: ...Index Page 444 7750 SR OS Interface Configuration ...