Revertive Switching
The APS implementation also provides the revertive and non-revertive modes with non-revertive
switching as the default option. In revertive switching, the activity is switched back to the working
port after the working line has recovered from a failure (or the manual switch is cleared). In non-
revertive switching, a switch to the protection line is maintained even after the working line has
recovered from a failure (or if the manual switch is cleared).
A revert-time is defined for revertive switching so frequent automatic switches as a result of
intermittent failures are prevented. A change in this value takes effect upon the next initiation of
the wait to restore (WTR) timer. It does not modify the length of a WTR timer that has already
been started. The WTR timer of a non-revertive switch can be assumed to be infinite.
In case of failure on both working and the protection line, the line that has less severe errors on the
line will be active at any point in time. If there is signal degrade on both ports, the active port that
failed last will stay active. When there is signal failure on both ports, the working port will always
be active. The reason is that the signal failure on the protection line is of a higher priority than on
the working line.
Bidirectional 1+1 Switchover Operation Example
outlines the steps that a bi-directional protection switching process will go through
during a typical automatic switchover.
Table 20: Actions for the Bi-directional Protection Switching Process
Status
APS Commands Sent in K1 and
K2 Bytes on Protection Line
Action
B -> A
A -> B
At Site B
At Site A
No failure
(Protection line is not in use)
No request
No request
No action
No action
Working line
Degraded in direction A->B
SD on working
channel 1
No request
Failure
detected,
notify A and
switch to
protection
line.
No action
Site A receives SD failure
condition
Same
Reverse
request
No action
Remote failure detected,
acknowledge and switch
to protection line.
Site B receives Reverse
request
Same
Same
No action
No action
Содержание 7710 SR SONET
Страница 6: ...Page 6 7710 SR OS Interface Configuration Guide Table of Contents...
Страница 8: ...Page 8 7710 SR OS Interface Configuration Guide List of Tables...
Страница 10: ...Page 10 7710 SR OS Interface Configuration Guide List of Figures...
Страница 14: ...Preface Page 14 7710 SR OS Interface Configuration Guide...
Страница 16: ...Getting Started Page 16 7710 SR OS Interface Configuration Guide...
Страница 18: ...Page 18 7710 SR OS Interface Configuration Guide Configuration Notes on page 107...
Страница 166: ...Service Management Tasks Page 152 7710 SR OS Interface Configuration Guide...
Страница 354: ...Multi Chassis Redundancy Commands Page 328 7710 SR OS Interface Configuration Guide...
Страница 494: ...Standards and Protocols Page 494 Standards and Protocols...
Страница 496: ...Index Page 496 7710 SR OS Interface Configuration Guide...