100W High Voltage Power Supply Connections
7705 SAR-A Chassis Installation Guide
85
Environmental Specifications
Notes
:
1.
Not applicable to DIN rail-mounted hardware.
2.
Enclosure classification is as defined in IEC 60529.
Table 20: 100W High Voltage Power Supply Environmental Specifications
Parameter
Description
Normal operating temperature
–40 to 149ºF
(–40 to 65ºC)
Cold start temperature
–40ºF (–40ºC)
Relative humidity
5 to 95% (non-condensing)
Cooling
Convection
Altitude range
Between 1033 ft (315 m) below sea level and 6562 ft
(2000 m) above sea level
Earthquake
Suitable for high-risk areas (Zone 4/California, for short-
duration disturbance)
Enclosure classification
IP67
Operating voltage range (DC)
88 VDC to 300 VDC
Operating voltage range (AC)
85 VAC to 264 VAC
Input current
1.5 A maximum at 95 VAC
0.7 A maximum at 220 VAC
1.65 A maximum at 88 VDC
Input frequency
47 Hz to 63 Hz
Rated output voltage (DC)
54 VDC
Maximum output current
2.1 A