Timing link failed
...................................................................................................................................................................................................................................
Alarm identifier
TLINKcFLR
Information
The timing reference signal, incoming at a line timing port, is not acceptable
as timing source.
Alarm category
Transmission
ASAP
timing
Alarm severity
(default setting)
Deferred
Reporting state
(default setting)
Reported
Local indications
–
Cause
The alarm was generated because:
•
Timing link may be failing.
•
Timing link reference signal is below an acceptable value.
•
The frequency deviation exceeds the tolerable limits.
Actions
Check equipment in the upstream far end station.
Check upstream cabling.
Note(s)
1643 AM and 1643 AMS systems only support the monitoring of one timing
reference at a time. This means that for standby references, no timing link
failure (due to frequency deviations for example) can be reported.