STM-1 MS Near-end severely ES threshold crossing 24-hrs
...................................................................................................................................................................................................................................
Alarm identifier
MS1NSEScTHR24
Information
The STM-1 Multiplex Section near-end severely errored seconds counter
exceeded the provisioned threshold during a 24-hour monitoring period.
Alarm category
Quality of service (performance monitoring)
ASAP
sdhMS
Alarm severity
(default setting)
Information
Reporting state
(default setting)
Not Reported
Local indications
–
Cause
Possible causes are:
•
Dirty optical connector(s).
•
Equipment fault(s) in the upstream station.
Actions
Check upstream external cabling or equipment.