background image

QUICK PROGRAMMING GUIDE 912-TT DVB-S/S2 TO DVB-T

ENG

Frequency

471.25

MHz

Attenuation

14

dB

Bandwith

MHz

8

Mode

8K

8K

2K

Modulation

64QAM

QPSK

16QAM

64QAM

FEC COFDM

7/8

7/8

2/3
3/4
5/6

1/2

Guard interval

1/32

1/32

1/16
1/8
1/4

Cell ID

 0

TSID

1078

(COD) Coded service 1

(COD) Coded service 2
(FTA) Free to air service 1

(FTA) Free to air service 3

BW total

81%

Orig Net Id

Network ID

1

1

15%

13%
17%
17%
19%

TV

TV
TV
TV
TV




CAM

Services

(FTA) Free to air service 2

If the output is programmed by frequency, enter the 
frequency using the numeric keypad. Then press T to 
transmit.
Enter the attenuation at the output of the module 
using the numeric keypad. Then press T to transmit.

Select the offset of the output frequency from the options 
available. Then press T to transmit.

Select the bandwidth of the output channel: 6, 7 or 8 
MHz. You can do this using either the numeric keypad or 
the pull-down menu. Then press T to transmit.

Select the number of carriers mode in the output channel. 
Then press T to transmit.

Select the type of modulation of the output channel. Then 
press T to transmit.

Select the output forward error correction rate (FEC 
COFDM). Then press T to transmit.

Select the guard interval of the output signal. Then press 
T to transmit.

You can enter a number of up to 5 digits as the cell 
identifi er using the numeric keypad. Then press T to 
transmit.

Press the READ key to obtain a reading of the services 
available in the input transponder.
Select the services that you wish to distribute, marking 
them with 

(by pressing the OK key). It is recommended 

that you should not use more than 90% of the available 
BW.
Once the desired services have been selected, press T 
to transmit.
Using the numeric keypad, you can enter a TS identifi er 
(TSID), should that be necessary for your installation. 
Then press T to transmit.

Set the programming switch of the 912-TT module to the OFF position. The programming 

indicator light will now go out.

OK+



+OK+T

OK+



+OK+T

T

READ

OK+



+OK

T

T

T

T

OK+



+OK+T

or

OK+



+OK+T

T

or

OK+



+OK+T

OK+



+OK+T

OK+



+OK+T

Off set

0

0

+1/6
-1/6
+1/8
-1/8

MHz

The status of the NIT table is shown in grey if no relevant 
information is available; in green if the NIT table is 
correct; and in red if the NIT table contained in the 
module is incorrect.

NIT table

No information

Valid

Invalid

Not generated