Repair & Adjustment Hints
AE 6890 Jumper settings, Power and Channel options
Jumpers at detachable front section board
To open: take off front section, remove 4 screws
Jumper section A:
Selecting the initial factory default frequency. (1 = solder jumper or 0 Ohm resistor
added) Factory default is version 3 jumpers added for Germany
dE
Version A0 A1 A2 Country
DISPLAY,CHANNEL
1
1
0
0
UK
U(FM40CH 4W)
2
0
1
0
Spain (Italy)
E (F40 4W/AM40 4W)
3
1
1
0
GERMANY
DE(FM80 4W/AM40
1W)
4 0 0 1
EU
EU(FM40 4W/AM40
1W)
5 0 1 1 CEPT(FM) EC(FM40
4W)
6
1
1
1 POLAND(-5K) Po(FM40/AM40 4W)
Jumper section B
:
Enable 240CH by adding 0 OHM or solder jumper.
Default setting: no jumper, 240 CH is not allowed
Jumper section C:
Default: Enable MULTI Standard selection by user: 0 Ohm or solder jumper added
Disable Multi Standard selection: delete 0 Ohms or delete solder jumper.
Содержание AE 6890
Страница 5: ...Main board with components values ...