since 1928
ALBIN PUMP ALP
PERISTALTIQUE PUMP
INSTRUCTION MANUAL
ALP Instruction Manual -2011EE-GB.indd 1
21/07/11 20:48
Страница 1: ...since 1928 ALBIN PUMP ALP PERISTALTIQUE PUMP INSTRUCTION MANUAL ALP Instruction Manual 2011EE GB indd 1 21 07 11 20 48...
Страница 2: ...ct loss due to a hose burst It is the operator s re sponsibility to prevent pumped liquid loss with additional hose rupture detectors and or automatic shut down valves Check 2 4 conditions of guarante...
Страница 3: ...removal ALP09 to ALP25 6 2 2 Hose replacement ALP09 to ALP25 6 2 3 Hose removal ALP30 to ALP45 6 2 4 Hose replacement ALP30 to ALP45 6 3 Rollar ajustment 6 3 1 Hose removal ALP09 to ALP25 6 3 2 Hose r...
Страница 4: ...Contact your ALBIN PUMP distributor if you notice a potential danger during the use of the pump 2 3 TRAINING OF THE USER AND INSTRUCTIONS Every person who installs uses or performs any operations of m...
Страница 5: ...etc 3 2 OPERATION PRINCIPLE PHASE 3 As soon as at the discharge side the rollar is detached from the hose the other rollar diametrically opposite is already in compression thus avoiding an internal p...
Страница 6: ...LEXAN LEXAN 4 FRAME ELECTROPLATED STEEL ELECTROPLATED STEEL 5 ROTOR ALUMINIUM ALUMINIUM 6 ROLLAR BRACKET ELECTROPLATED STEEL ALUMINIUM 7 ROLLAR NYLATRON ALP25 ALUMINIUM ALUMINIUM 8 INSERT STAINLESS S...
Страница 7: ...tenance manual provided with the pump to know the quantity of lubricant requested as well as the periodicity of oil change 3 6 ELECTRICAL MOTORS The standard motors provided on our pumps are squirrel...
Страница 8: ...adequately ventilated to releive the heat generated by the pump Leave a space behind the motor ventilatior hood so as not to obstruct air intake 4 4 PIPING Suction line piping The internal diameter of...
Страница 9: ...igures don t match the pump speci fications 4 5 LIFTING THE PUMP Pumps are provided with two lift holes placed on the upper part of the frame While lifting the pump respect the following points Lift t...
Страница 10: ...valves have to be closed to minimize product loss c Always carry clothes and necessary protection according to the pumped product d Respect all security and enviromental rules necessary for the manipu...
Страница 11: ...and place it inside the pump casing 5 Position the upper connector against the pump cas ing inlet Place the top hose locking 23 and position the collar 14 in it s groove Tighten the collar screw 6 Rep...
Страница 12: ...ake sure the rollars are in the same position as before 4 Make a U bend with the hose and place it inside the pump casing 5 Position the upper connector against the pump casing inlet Place the top hos...
Страница 13: ...lar Loosen bracket screws 4 Place the sight glass on the pump cover 5 Run the pump and place the palm of your hand over the inlet port suction side and check if the fixed rollar is ajusted enough to c...
Страница 14: ...ower supply 5 Run the pump Place the palm of your hand over the inlet suction side and check whether the pump is compressing the hose enough to create a vacuum If the vacuum isn t sufficient add succe...
Страница 15: ...mance of hoses is reduced at the end of this expiry date due to the ageing of rubber 1 Pump hose replacement In prevention change the pump hose after 90 of the life time of the first hose see 6 2 2 Ge...
Страница 16: ...Hose life time is too short Incompatibility of the hose with the pumped product Make sure the compatibility of the hose with your product and contact your Albin distributor Discharge pressure too hig...
Страница 17: ...ALP since 1928 17 9 CHARACTERISTICS AND TECHNICAL SPECIFICATIONS 9 1 PERFORMANCE CURVES ALP Instruction Manual 2011EE GB indd 17 21 07 11 20 49...
Страница 18: ...95 132 61 222 127 165 180 156 170 10 28 20 197 19 352 6 ALP 13VM 126 95 132 61 222 127 165 180 156 170 10 28 20 197 19 502 6 ALP 17F 187 131 188 73 290 167 220 235 180 200 13 5 40 5 35 235 5 25 427 6...
Страница 19: ...64 148 556 330 330 380 550 600 22 66 5 55 655 5 45 672 5 14 ALP 30VM 345 226 364 148 556 330 330 380 550 600 22 66 5 55 655 5 45 812 5 14 ALP 45F 455 287 456 157 672 385 420 470 650 700 40 79 70 786 6...
Страница 20: ...de Albin Pump AB 1 1 REV A3 SIZE DIM BRUT PROJECT N CUSTOMER DWG N TITLE Serial number ALP09 13 17 PUMP TYPE Code Oratio MATERIAL Mat riau non sp cifi General clearance WEIGHT PART NUMBER SCALE EXPLOD...
Страница 21: ...risation expresse de Albin Pump AB 1 1 REV A3 SIZE DIM BRUT PROJECT N CUSTOMER DWG N TITLE Serial number ALP25 30 45 PUMP TYPE Code Oratio MATERIAL Mat riau non sp cifi General clearance WEIGHT PART N...
Страница 22: ...COLLAR X X X 15 ROTOR SHAFT X 16 SPACER X 18 CIRCLIP SHAFT X 19 CIRCLIP CASING X 20 HOSE X X X 21 SCREW COVER X X X 22 WASHER COVER X X X 23 HOSE LOCKING X X X 24 SCREW BRACKET X X X 25 WASHER BRACKET...
Страница 23: ...re than 60dB during their operation TEMPERATURE The cover and the pump casing can become very hot due to the friction on the hose and liquid temperature If you need to limit the pump temperature pleas...
Страница 24: ...ipulates all the data concerning his process and appli cation of the pump is the only evidence in case of dispute The non observance of this data will disengage the responsibility of ALBIN PUMP SAS Th...
Страница 25: ...7 Solvents incompatible with pumps seals 8 Possible leakage of pumped liquid 9 Drive of the pump 9 1 Electric installation of the motor or the motor reducer of the pump 9 2 Ground connection of the pu...
Страница 26: ...of the pumping part and Protection of the transmission part 2 Protection of the pumping part The heating of the pumping part is directly related to the functioning temperature of the hose The lifespan...
Страница 27: ...emperature of the pumped product These working limits are mainly imposed by the heating of the hose on which the lifespan is strongly dependent Within the framework of an application required to chang...
Страница 28: ...The possible leakages of liquid by the pump s seals do not generate a risk of ignition as long as the explosive atmosphere surrounding the material corresponds to the type of atmosphere for which it w...
Страница 29: ...motor or motor reducer must have ATEX characteristics adapted to recognized use group gas IIB class of temperature T4 and must explosion proof 10 ATEX characteristics of the pumping installation A pum...
Страница 30: ...TYPE ALP II 2 G T4 or II 3 G T4 N series Year The marking of the Albin groups is of type ALBIN Gpe ALP II 2 G T4 or II 3 G T4 N series Year In the case of a pumping group ATEX certified materials wil...
Страница 31: ...rned 1 0 COMPAGNY NAME Address City Postal code Country T l phone Fax number 2 0 PUMP 2 1 SERIAL NUMBER 2 2 Has the pump been used YES NO If yes please complete all the following paragraphs If no plea...
Страница 32: ...ion Volumetric pump hose pump SECTION 2 0 Applicable directives Machinery directives 89 392 EEC 89 655 EEC 91 368 EEC 93 44 EEC SECTION 3 0 Label SECTION 4 0 Statement We declare under our responsibil...
Страница 33: ...atives please visit www albinpump com ALBIN PUMP reserves the right to incorporate our latest design and material changes without notice or obligation Design features materials of construction and dim...