Страница 1: ...since 1928 ALBIN PUMP AD AIR OPERATED FLOATING DIAPHRAGM PUMPS INSTRUCTION MANUAL AD Instruction Manual 2011EE GB indd 1 25 07 11 09 45...

Страница 2: ...ity with COUNCIL DIRECTIVE on the approximation of the laws of the Member States relating to Machinery 98 37 EG Declaration of incorporation Directive 98 37 EG Annex IIB AD Air Operated Diaphragm Pump...

Страница 3: ...d pump installation 4 3 Venting exhaust air 4 4 Before starting the pump 4 5 How to start operate and stop the pump 4 6 Routine maintenance 5 DIRECTIONS FOR DISASSEMBLY AND REASSEMBLY 5 1 Disassembly...

Страница 4: ...missing parts a report should be drawn up and presented to the carrier instantly Notify your ALBIN PUMP distributor All pumps have the type specification Type printed on the name plate which is locat...

Страница 5: ...iaphragms PTFE can operate continuously between 30 C and 85 C Pump housing PP polypropylene can be used in the interval 0 C and 85 C Aluminium can be used in the same interval as the diaphragms Inside...

Страница 6: ...thout damaging the environment or nearby equipment Always install a separate shut off valve for the air supply easily accessible for manoeuvring Pressure variations may cause vibrations in the piping...

Страница 7: ...how the check valves are opening and closing In the AD pump the diaphragms are not fixed to the shaft Thanks to this Flexible Diaphragm Suspension FDS invention and the spring at the shaft end the dia...

Страница 8: ...T TEFLON PTFE with EPDM carrier 1 6 STANDART PARTS 17 7 5 1 14 15 13 9 11 12 4 8 10 3 2 16 2 18 1 Pump housing 2 Lid 3 Diaphragm 4 Air motor 5 Shaft 6 Shaft spring option 7 Shaft bushing 8 Insert Inl...

Страница 9: ...16 1 4436 Spring Stainless steel 316 1 4401 Check valve retainer 30 60 PPS Tedur 40 glass Check valve retainer 120 Stainless steel 316 1 4436 Check valve in and out PEEK O ring Teflon PTFE Screw Stain...

Страница 10: ...nless steel 304 1 4301 2332 Air gaskets NBR nitrile Muffler HDPE polyethylene Air O rings NBR nitrile Externals Material AISI DIN SS Foot plate Stainless steel 304 1 4301 2333 Rubber foot NBR nitrile...

Страница 11: ...water at 7 bar air pressure and fully open inlet and discharge ports The readings were made at a distance of 1 one metre on the same level as the pump Front 79 5 dB A Left 75 5 dB A Right 74 9 dB A Be...

Страница 12: ...2 Reduction for suction lift Important To obtain a long diaphragm life and a high efficiency low air consumption always select a pump which has a max capacity which is as least 1 5 times higher than t...

Страница 13: ...flow 30 l min along the horizontal axis Go vertical to the intersection with the required air pressure 3 5 bar and read the air consumption to the left In the example 180 l min Fluid flow lpm 0 50 10...

Страница 14: ...CTION FOR SUCTION LIFT AD15 AD120 Viscosity cP 0 10 20 30 40 50 60 70 80 90 100 0 500 1000 1500 2000 2500 3000 3500 Capacity reduction Suction lift m 0 10 20 30 40 50 60 70 80 90 100 0 2 4 6 8 10 Capa...

Страница 15: ...Flow Pressure A 6 bar air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 50 100 150 200 250 300 350 0 5 10 15 20 25 30 35 40 45 A B C Air consumption lpm Fluid flow lpm A 6...

Страница 16: ...air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 50 100 150 200 250 300 350 0 5 10 15 20 25 30 35 40 45 A B C Air consumption lpm Fluid flow lpm Flow Air consumption A 6...

Страница 17: ...id flow lpm A 6 bar air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 50 100 150 200 250 300 350 400 450 0 10 20 30 40 50 60 70 80 90 A B C Air consumption lpm Fluid flow l...

Страница 18: ...Fluid flow lpm A 6 bar air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 1 2 3 4 5 6 7 0 20 40 60 80 100 120 140 A B C Fluid outlet pressure Bar Fluid flow lpm Flow Pressur...

Страница 19: ...o optimise a good product flow to the pump Use a reinforced non collapsible hose of at least the same inner diameter as the suction port Always consider the following when designing a system make sure...

Страница 20: ...so be at least the same diameter as the pump port By increasing the diameter of the piping the friction losses decrease Before using the pump for the first time all external screws and nuts should be...

Страница 21: ...educes the pump noise As shown in the illustration a larger muffler can be fitted to further reduce noise 4 4 BEFORE STARTING THE PUMP Ensure that the suction pipes hoses are free from debris It is ad...

Страница 22: ...re is less than the fluid discharge pressure 4 6 ROUTINE MAINTENANCE Ensure that the suction pipes hoses are free from debris It is advised to run the pump with a com patible fluid e g water prior to...

Страница 23: ...the AD pump are 2 pieces 13 mm combination spanners 2 different hexagon allen keys 2 5 and 5 mm It is also advised to use a small screwdriver to lift O rings and rubber packings For the reassembly a...

Страница 24: ...5 and replace if worn Replace the check valves 6 7 if they are worn or distorted It is recommended always to change the PTFE O rings 8 9 once the retainers have been removed 5 1 3 COVERS AND AIR DIST...

Страница 25: ...the inlet insert 5 4 Remove the CEG lockring 7 and remove the muffler 8 5 2 REASSEMBLY 5 2 1 AIR MOTOR AND MANIFOLDS 1 Fit the muffler 8 and the CEG lockring outlet 7 2 Fit the inlet insert 5 and the...

Страница 26: ...LVES 1 Push the shaft bushing 5 in place Fit two new PTFE O rings 8 and 9 in the pump housing 10 Fit the inlet check valve 6 on one of the retainers 4 Push the retainer firmly in place so it snap lock...

Страница 27: ...ed by the stud bolts so there is no risk they come off place 2 Tighten the cap nuts 4 with 22 Nm 5 2 5 AIR MOTOR 1 Fit the complete air motor 2 with air motor gaskets 3 on top of the pump housing Tigh...

Страница 28: ...101 118 147 147 123 1 4 3 8 2 5 3 7 AD30 14 145 2 5 64 5 130 97 6 141 101 118 147 147 123 3 8 3 8 2 5 3 7 AD60 14 164 2 5 74 149 97 6 141 101 118 147 147 141 3 4 3 8 3 6 4 9 AD120 14 210 2 5 97 195 9...

Страница 29: ...29 AD since 1928 7 0 EXPLODED VIEWS AND PART LISTS 7 1 PUMP AD Instruction Manual 2011EE GB indd 29 25 07 11 09 46...

Страница 30: ...exagon screw all incl in Check valve kit with retainer 12 Checkvalve outlet all incl in Check valve kit and Check valve kit with retainer 13 Opening limiter all incl in Check valve kit and Check valve...

Страница 31: ...n Air motor kit and Muffler standard kit 29 CEG lockring inlet all Incl in Air motor kit and Air connection kit 30 Insert Inlet all Incl in Air motor kit and Air connection kit 31 CEG lockring outlet...

Страница 32: ...motor Gasket External 2 K102 101 Pos Description Qty 7 Checkvalve Inlet 60 2 12 Checkvalve Outlet 60 1 9 O ring Teflon 18 2 8 O ring Teflon 19 2 13 Opening limiter 60 1 14 Shaft Bushing 60 1 6 Checkva...

Страница 33: ...tion Qty 1 Pumphousing AL 120 1 K109 103 Pos Description Qty 1 Pumphousing AX 120 1 K109 203 Pos Description Qty 1 Pumphousing PP 120 1 K109 303 Pos Description Qty 1 Pumphousing PX 120 1 K109 001 Pos...

Страница 34: ...the seats Replace the shaft bushing pos 14 if it is worn Erratic pump action heavy pulsation Check the diaphragms pos 5 Check that the air motor pivot pos 31 moves freely and that the rubber seals pos...

Страница 35: ...AD since 1928 AD Instruction Manual 2011EE GB indd 35 25 07 11 09 46...

Страница 36: ...please visit www albinpump com ALBIN PUMP reserves the right to incorporate our latest design and material changes without notice or obligation Design features materials of construction and dimensiona...