![ALBERTI NEW MEDIJET Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/alberti/new-medijet/new-medijet_use-and-maintenance-manual_2889535013.webp)
ALBERTI INTERNATIONAL NEW MEDIJET
Pagina 13 di 20
poured into civic drains.
For further information please contact your local committee for
exhaust oil drainage.
17.
WARRANTY
For as much as the machine’s warranty is concerned apply to paragraph
19 WARRANTY
CONDITIONS
and
WARRANTY CERTIFICATE
given with the machine. The same is valid
only if filled in completely and sent to ALBERTI INTERNATIONAL S.r.l. within 10 days from the
machine’s purchase.
18.
DRAWBACKS: CAUSES AND SOLUTIONS
PROBLEM
CAUSE
SOLUTIONS
WATER DOESN’T COME OUT
Dirty water filter
Blocked infeed valves
Clogged lance nozzle
Clean or replace
Check
Clean
WEAK OR IRREGULAR
PRESSURE
The detergent valve is open
and takes in air
Insufficient water supply
The pump intakes air
Worn out valves
Worn out/not suitable nozzle
Worn out gaskets
Check
Check the capacity
Check
Replace
Replace
Clean or replace
Replace
THE BURNER DOESN’T TURN ON
Excessive air intake
Dirty fuel filter
Dirty fuel pump filter
Dirty burner nozzle
Faulty thermostat
Broken/blocked electrovalve
Insufficient electrodes spark
Worn out motor pump joint
Absent/insufficient voltage
Check
Replace
Clean or replace
Replace.
Replace
Replace
Check
Replace
Check
NOISY CLEANER
Air intake;
Worn out/dirty/blocked valves;
Exceeding water temperature
Check the intake
hoses
Clean or Replace
Decrease the
temperature
PRESENCE OF WATER IN THE OIL
Worn out water/oil rings
High percentage of humidity in the air
Replace
Check
OIL LEAKAGE FROM HEAD
Worn out O-rings of the seal system
Repalce OR
MOTOR DOESN’T START WHEN
PRESSING THE SWITCH
The plug is not working due to
overheating
Check the plug, the
cable and the ON/OFF
switch
MOTOR STOPS SUDDENLY
Intervention of the thermic protection due
to overheating
Check the tension.