19
8.2
Messages from the Note validator
8.2.1 BillyOne / OryOne Validator
During operation, the amount of consecutive red flashes produced by the entry slot indicates the
possible malfunctions (see chart below):
8.2.2 Front bezel flashing blue
When the front bezel flashes blue, it means that either the stacker has been removed, or the
detection sensor has gone faulty.
8.2.3 Fraud-fishing protection
The banknote reader is equipped with a security device that gets activated in the event of fishing
fraud attempts repeated over a period of time.
This device can be set through the dip-switch SW2 (DS-row on the Validator side) to operate in a
"soft" mode (* DS2 = ON) or in "extended" mode (** DS2 = OFF).
(*) Dip-Switch SW2 ON
Any attempt
at “fishing” will cause the note to be rejected, without showing any visible
signal.
(**) Dip-Switch SW2 OFF
Attempt
Validator reaction
Do as described below
1
th
Remains in service
-
2
th
Remains in service
-
3
th
> error (3 red flashes)
Reset (switch off then on)
4
th
> error (3 red flashes)
Reset (switch off then on)
After the 5th fraud attempt (3 yellow flashes), it is necessary to wait for automatic restore
of service. Take care not to switch the device off.
NOTICE: no error status will be transmitted to the machine, so that the latter does not go out of
service, and will therefore continue to maintain the other functions working.
nr of red flashes
Description
1
Validator is open
2
Jammed banknote
3
Fraud attempt detected
5
Adjust optic sensors
7
Stacker full (OryOne Only)
9
Low power supply
11
Check operation of the e efficiency of the validator motor
12
Check operation of the e efficiency of the stacker motor
(OryOne only)
14
ROM error