Albalá Ingenieros | Manual
TTD3000C03
The following functions of the TTD3000C03 can be performed remotely:
- Selection of the operating mode: manual for use as a distributor and automatic or
semiautomatic for use as an automated switch.
- Selection of the input to be distributed to the outputs of each section.
- Configuration of the signal failure criteria.
- Supervision of the status of the input signals.
4.3.1. Details of the TTD3000C03 registers
The TTD3000C03 module provides control and status registers that can be read and
written by means of specific commands described in the communication control
module user manuals.
The parameter information grouped in the CONTROL or RAM sections is stored in
volatile memory. Any modifications to the parameters will be lost when the module
power supply is disconnected unless the "EEPROM Save" button within the software
has been pressed.
The STATUS section parameters are read-only and cannot be modified.
The EEPROM section parameters are rarely used and are stored directly in non-volatile
memory.
The parameters that can be controlled and supervised remotely for each version of
the firmware are listed below:
VERSION 1.X
CONTROL
Name
add
ext
msk
snmp trap
Description
MODE
0x00
0x03
Y
Y
Allows selecting the switching mode
0=Full auto, 1=Half auto, 2=Manual
INPUT_A
0x01
0x01
Y
Y
Selected input (Section A)
0=Input A, 1=Input B
INPUT_B
0x01
0x02
Y
Y
Selected input (Section B)
0=Input A, 1=Input B
INPUT_A_LV_F_MSK
0x02
0x01
N
N
Allows masking signal presence fail (Section A)
0=Disabled, 1=Enabled
INPUT_A_FR_F_MSK
0x02
0x02
N
N
Allows masking signal frequency fail (Section A)
0=Disabled, 1=Enabled
INPUT_B_LV_F_MSK
0x02
0x04
N
N
Allows masking signal presence fail (Section B)
0=Disabled, 1=Enabled
INPUT_B_FR_F_MSK
0x02
0x08
N
N
Allows masking signal frequency fail (Section B)
0=Disabled, 1=Enabled
IMPEDANCE
0x03
0x01
Y
N
Allows selecting the output impedance
0=50 ohms, 1=75 ohms
FREQ_RANGE
0x03
0x02
Y
N
Allows selecting the frequency measure range
0=Hz, 1=kHz
EXPECTED_FREQ
0x04
0xFFFF
Y
N
Allows selecting the expected frequency
= x/10 (k)Hz
FREQ_FAIL_OFFSET
0x06
0xFF
Y
N
Allows selecting the frequency offset that causes fail
= x/10 (k)Hz
21
Содержание TTD3000C03
Страница 2: ...TTD3000C03 ...
Страница 4: ...TTD3000C03 ...
Страница 7: ...Albalá Ingenieros Manual TTD3000C03 1 3 Block diagram 7 ...
Страница 8: ...Albalá Ingenieros Manual TTD3000C03 TTD3000C03 8 ...
Страница 10: ...Albalá Ingenieros Manual TTD3000C03 TTD3000C03 10 ...
Страница 16: ...Albalá Ingenieros Manual TTD3000C03 TTD3000C03 16 ...
Страница 24: ...Albalá Ingenieros Manual TTD3000C03 TTD3000C03 24 ...
Страница 25: ...Albalá Ingenieros Manual TTD3000C03 6 REGULATIONS 25 ...
Страница 26: ...Albalá Ingenieros Manual TTD3000C03 TTD3000C03 26 ...
Страница 28: ...Albalá Ingenieros S A Medea 4 28037 Madrid Spain 34 913274453 www albalaing com info albalaing com ...