1.2. Features

• Routing switcher for analog or digital video signals.

• Provides:

- Twelve inputs.

- Two independent outputs.

• Switching can be triggered:

- Immediately after receiving a command.

- In the vertical interval between two fields as per SMPTE RP 168.

- In the vertical interval between two frames as per SMPTE RP 168.

• Maintains the last selection in case of power supply failure.

• Multiple routing switches in the same mounting frame can be configured to switch

simultaneously to create a component routing switch.

• Module control and supervision can be done remotely when the mounting frame is

equipped with a communications controller module.

• One UR3000 mounting frame can house up to 12 AVP1222C01 modules. If power

supply redundancy is required and FA3000 or FA3001 modules are used then only 10
modules can be housed in the mounting frame. If PSU3300 or PSU3301 modules are
used for this purpose then up to 12 modules can be installed.

• One UR3100 mounting frame can house up to three AVP1222C01 modules.

• Low power.

6

Содержание AVP1222C01

Страница 1: ...AVP1222C01 12 INPUTS TO 2 INPUT ANALOG DIGITAL VIDEO ROUTING SWITCHER Version 1 0 Albalá Ingenieros S A Medea 4 28037 Madrid Spain 23 June 2016 Albalá Ingenieros S A All rights reserved ...

Страница 2: ...AVP1222C01 ...

Страница 3: ...n 11 3 2 Safety instructions 11 3 3 Environmental considerations 12 3 4 Power considerations 12 3 5 Installing the module in the mounting frame 12 3 6 Interconnection 14 3 6 1 Analog video connections 14 4 OPERATION 17 4 1 Front panel description 17 4 2 Functional description 18 4 3 Module remote control and supervision 20 4 3 1 Details of the AVP1222C01 registers 21 5 GLOSSARY 23 6 REGULATIONS 25...

Страница 4: ...AVP1222C01 ...

Страница 5: ... same mounting frame for simultaneous switching in program material that contains video and analog audio It is possible to monitor the AVP1222C01 status remotely using a communications controller module installed in the same mounting frame In addition certain controller modules provide SNMP management and the ability to record events in a file including date and time information for further analys...

Страница 6: ...ng switches in the same mounting frame can be configured to switch simultaneously to create a component routing switch Module control and supervision can be done remotely when the mounting frame is equipped with a communications controller module One UR3000 mounting frame can house up to 12 AVP1222C01 modules If power supply redundancy is required and FA3000 or FA3001 modules are used then only 10...

Страница 7: ...Albalá Ingenieros Manual AVP1222C01 1 3 Block diagram 7 ...

Страница 8: ...Albalá Ingenieros Manual AVP1222C01 AVP1222C01 8 ...

Страница 9: ...tputs 2 Separation between outputs 65 dB up to 30 MHz DC voltage 20 mV Analog video signal Gain 0 0 1 dB at 1 MHz Input to output coupling DC Input to output delay 2 5 ns 1 ns Dynamic range 2 V Bandwidth 0 1 dB 30 MHz 3 dB 200 MHz Differential gain 0 1 Differential phase 0 1 S N ratio unweigthed with ref 0 7 VRMS 70 dB RMS from 40 Hz to 6 MHz Input to output isolation 60 dB at 30 MHz Input to outp...

Страница 10: ...Albalá Ingenieros Manual AVP1222C01 Input to output isolation 50 dB at 140 MHz General Maximum power supply current 120 120 mA Operating temperature range 0 50 C Approximate weight 325 g 10 ...

Страница 11: ...ns This equipment must be connected to a mains outlet with a protective earth connection Never use extension cords that do not have protective earthing connection The lack of an effective electrical connection between the ground pin in the mains input connector of the equipment and the protective earth of the electrical power distribution can cause serious harm All modules of the Albalá Ingenieros...

Страница 12: ...l the AVP1222C01 module with the rear board in the mounting frame are 1 Disconnect all power cords from the power supplies of the mounting frame 2 Remove the blank panels covering the front and rear of the empty bays chosen for installing the AVP1222C01 in the mounting frame 3 Install the XVP1222P01 rear board ensuring that its 12 pin connectors are properly aligned with the mounting frame s matin...

Страница 13: ...Albalá Ingenieros Manual AVP1222C01 Details for installation of the module in 3 RU mounting frames Details for installation of the module in 1 RU mounting frames 13 ...

Страница 14: ...nnection board is not designed to withstand mechanical stress The wiring must be fastened properly to the frame where the mounting frame is housed to prevent the rear board from supporting the weight of the cables 3 6 1 Analog video connections The analog video inputs use BNC connectors with an impedance of 75 Ω The analog video outputs use BNC connectors and have an impedance of 75 Ω For analog v...

Страница 15: ...Albalá Ingenieros Manual AVP1222C01 must be used 15 ...

Страница 16: ...Albalá Ingenieros Manual AVP1222C01 AVP1222C01 16 ...

Страница 17: ...ignificance of the front panel indicators of the AVP1222C01 module and their remote control and monitoring ability 4 1 Front panel description The appearance of the front panel and the elements it contains are shown in the following illustration Front panel of the AVP1222C01 17 ...

Страница 18: ...d The switching action between the different inputs can be performed with four different switching times depending upon the configuration of the preselector and the presence or absence of a vertical sync signal When the switching time is set to FAST the preselector will switch as soon as it receives a command to do so Switching also takes place immediately even when commanded to do so at a differe...

Страница 19: ...Albalá Ingenieros Manual AVP1222C01 19 ...

Страница 20: ...vision The AVP1222C01 requires remote control for configuration In order to perform remote configuration and supervision of the module an optional TL3000 family remote communications controller must be installed in the mounting frame The main function of the communications control module is to interface between a 10 100 Ethernet port an EIA RS232 or an EIA RS485 serial port and the internal bus of...

Страница 21: ...ed The STATUS section parameters are read only and cannot be modified The parameters that can be controlled and supervised remotely for each version of the firmware are listed below VERSION 1 X CONTROL Name add ext msk snmp trap Description OUTPUT1 0x00 0x0F Y N Input routed to output 1 Input x 0 None OUTPUT2 0x00 0xF0 Y N Input routed to output 2 Input x 0 None SWITCH_MODE 0x01 0x0F Y N Allows se...

Страница 22: ...Albalá Ingenieros Manual AVP1222C01 AVP1222C01 22 ...

Страница 23: ...Albalá Ingenieros Manual AVP1222C01 5 GLOSSARY BNC Bayonet Neill Concelman connector 23 ...

Страница 24: ...Albalá Ingenieros Manual AVP1222C01 AVP1222C01 24 ...

Страница 25: ...Albalá Ingenieros Manual AVP1222C01 6 REGULATIONS SMPTE RP 168 2009 Definition of Vertical Interval Switching Point for Synchronous Video Switching 25 ...

Страница 26: ...Albalá Ingenieros Manual AVP1222C01 AVP1222C01 26 ...

Страница 27: ...Albalá Ingenieros Manual AVP1222C01 7 VERSIONS Ver Date Description 0 0 13 06 2013 Preliminary Version 1 0 23 06 2016 First version ...

Страница 28: ...Albalá Ingenieros S A Medea 4 28037 Madrid Spain 34 913274453 www albalaing com info albalaing com ...

Отзывы: