Electrical Connections 

 
 
 
 
 
 
 
 

 
WALL CONTROL INSTALLATION 
Step1.

   (Fig.1) Remove appropriate knockout from wall control holder box and secure box onto wall using the four screws provided.     

 

Step2.

   (Fig.2) Use a flat screw driver to gently remove the face plate from the wall control. 

 

Step3.

   (Fig.3) Carefully remove the POWER and AIRFLOW buttons from the wall control. 

 
Step4.  (Fig.4) Pull wires through knockout and follow the single and multiple fan wiring diagram below; 
 
Step5.  (Fig.5&6) After the wiring is done, secure the wall control to the holder box using the two screws provided and replace the face plate.  
 
 
 
 
 
 
 
 
 
 
 

 

 
WIRING BOX  
Step1.

   (Fig. 1) Remove the wiring box cover from Tile Fan.

 

 

 

Step2.

   (Fig. 2) Push 

supply wires into Tile Fan’s “push-in” connector as shown in wiring diagram on next page.  

 

Step3.

   (Fig.3) Place wire connector neatly back into wiring box making sure all wires pass through the box cut out. Replace cover

 

 

NOTE; “Multiple Tile Fan installation” you can connect (and control) up to 20 Tile Fans from one wall control.  
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

   

Risk of Fire: Supply conductors (power wires) connecting the Tile Fan must be rated 

minimum of 90

°

C. If uncertain, consult an electrician. 

Risk of Electric Shock:   Disconnect the power at the fuse or circuit breaker before installing or servicing.  

Make certain no bare wires are exposed outside the wire connectors. 

 

 