Alarmtech AD 700 Скачать руководство пользователя страница 4

© 2016 Alarmtech 

4 / 4 

AD700 manual 1643en 

 

 

 

 

 

 

 

+12 V 

 

 

 

 

 

 

Remote-control of day and night mode and indication of 

To test the function of the detectors with the ADT 700 

the detector giving first alarm 

Connect the detectors (max. 20 pcs) in accordance with the 
following schedule and set the DIP-switches. 
DIP2=ON 

LED mode: AIS 

Control Unit 

+12 V  

+12 V  

Detector 1   Detector 2   Detector 3    Detector 4 … etc 

D/N 

AIS 

DIP3=OFF 

D/N polarity: DAY mode = open line or low 

Set the switches A  and B in  the position  showed  in    figure 

Control Unit 

+12 V  

+12 V  

Detector 1   Detector 2   Detector 3    Detector 4 … etc 

D/N 

AIS 

above The detectors are now in DAY mode and prepared for 
receiving signals from the ADT 700 (See Function-test of the 
alarm  relay  using  ADT  700).  When  testing  is  finished  the 
switch  B  must  be  open.  Otherwise  the  indication  of  first 
alarming detector will be blocked in NIGHT mode. 

This is the initial configuration. The detectors are now in DAY 
mode. There is no LED indication of an alarm, but the alarm 
relay will open in case of alarm. It is not possible to test the 
detectors with ADT 700. 

Function test of the alarm relay using the ADT 700 tester 

Start the testing by pressing the start button at the ADT 700 
at a distance of around 1 m from the detector. LED then starts 
to flash confirming it is set in test mode. The alarm relay is 

Control Unit 

Detector 1   Detector 2   Detector 3    Detector 4 … etc 

now open. End the test by pressing the ADT 700 stop button 

+12 V  

 

D/N 

 

AIS 

at  a  distance  of  1m  from  the  detector.  The  alarm  relay  will 
now close. The test will otherwise end up automatically after 
4 minutes. 

The detectors are now in NIGHT mode. There is no indication 
of an alarm. The information is stored in the Alarm memory. 
In case of alarm the relay will open. It is not possible to test 
the detectors with ADT 700. If the position of any DIP-switch 
is changed an alarm will be triggered. The alarm relay will fol- 
low the setting of DIP1. 

Function test of the alarm relay by connecting to terminal 4 
(D/N) 

Set  DIP3=OFF  (NIGHT  mode)  –  connect  +12V  to  terminal  4 
(D/N)  in  the  detector.  If  any  change  in  the  position  of  DIP- 
switches now is done, the alarm relay will open. 

Attention

: If DIP1 is in OFF mode, the relay will be open for 2 

Control Unit 

+12 V  

+12 V  

Detector 1   Detector 2   Detector 3    Detector 4 … etc 

D/N 

AIS 

Seconds only and then close. If DIP1 is in ON mode, the relay 
will be open and close when the power is switched off or if 
the mode is changed from DAY to NIGHT on terminal 4. 
Another alternative to close the alarm relay is to switch DIP3 
over to ON mode (D/N polarity). 

The detectors are now back in DAY mode. If some detectors 
have triggered an alarm during NIGHT mode, this will be indi- 
cated by LED light. The alarm relay follows the setting of DIP1. 
LED  will  flash  on  the  detector  that  triggered  the  first  alarm 
and  will  shine  firmly  on  the  other  alarming  ones.  When 
switching from DAY to NIGHT – all the detectors are reset. 

TECHNICAL DATA 

Type (thickness) of protected glass 

float (4 mm), laminated P2 (4 mm + 4 mm) 

Size of protected glass 

min 40×40 cm 

Max range 

9 m radius/165° 

 

Zone 3 = 1–2 m 

Range setting 

Zone 2 = 2–4 m 

 

Zone 1 = 4–9 m 

Supply voltage 

12 V DC (9 - 15 V DC) 

Max. voltage ripple 

2 Vpp at 12 V 

Voltage monitoring 

alarm at < 7 V ±0,5V 

Current consumption quiescent/alarm state 

26 mA/24 mA @ 12 V DC 

Alarm output 

relay 

Alarm contact rating 

50 mA, 50 V DC/peak AC, Rs ≤ 30 Ω 

Tamper contact rating 

50 mA/50 V DC/peak AC 

Alarm indication 

LED 

Environmental class EN50130-5:2011, VdS 2110 

Class I, 

Operating temperature range 

+5°C to +40°C 

Operating humidity range 

max. 93% RH 

Housing material 

ABS plastic white, brown or black color 

Dimensions: 

60x32x98 mm 

Security grade 

EN50131-2-7-1:2012, Grade 2, VdS Klasse B, SFS 1014-4 

Approvals 

VdS G104512 Class B, SBSC Alarm Class 2 

We reserve the right to changes without notice 