+12 V
Remote-control of day and night mode and indication of
To test the function of the detectors with the ADT 700
the detector giving first alarm
Connect the detectors (max. 20 pcs) in accordance with the
following schedule and set the DIP-switches.
DIP2=ON
LED mode: AIS
Control Unit
+12 V
A
+12 V
B
Detector 1 Detector 2 Detector 3 Detector 4 … etc
D/N
4
AIS
3
3
3
3
DIP3=OFF
D/N polarity: DAY mode = open line or low
Set the switches A and B in the position showed in figure
Control Unit
+12 V
A
+12 V
B
Detector 1 Detector 2 Detector 3 Detector 4 … etc
D/N
4
AIS
3
3
3
3
above The detectors are now in DAY mode and prepared for
receiving signals from the ADT 700 (See Function-test of the
alarm relay using ADT 700). When testing is finished the
switch B must be open. Otherwise the indication of first
alarming detector will be blocked in NIGHT mode.
This is the initial configuration. The detectors are now in DAY
mode. There is no LED indication of an alarm, but the alarm
relay will open in case of alarm. It is not possible to test the
detectors with ADT 700.
Function test of the alarm relay using the ADT 700 tester
Start the testing by pressing the start button at the ADT 700
at a distance of around 1 m from the detector. LED then starts
to flash confirming it is set in test mode. The alarm relay is
Control Unit
Detector 1 Detector 2 Detector 3 Detector 4 … etc
now open. End the test by pressing the ADT 700 stop button
A
+12 V
B
4
3
3
3
3
D/N
AIS
at a distance of 1m from the detector. The alarm relay will
now close. The test will otherwise end up automatically after
4 minutes.
The detectors are now in NIGHT mode. There is no indication
of an alarm. The information is stored in the Alarm memory.
In case of alarm the relay will open. It is not possible to test
the detectors with ADT 700. If the position of any DIP-switch
is changed an alarm will be triggered. The alarm relay will fol-
low the setting of DIP1.
Function test of the alarm relay by connecting to terminal 4
(D/N)
Set DIP3=OFF (NIGHT mode) – connect +12V to terminal 4
(D/N) in the detector. If any change in the position of DIP-
switches now is done, the alarm relay will open.
Attention
: If DIP1 is in OFF mode, the relay will be open for 2
Control Unit
+12 V
A
+12 V
B
Detector 1 Detector 2 Detector 3 Detector 4 … etc
D/N
4
AIS
3
3
3
3
Seconds only and then close. If DIP1 is in ON mode, the relay
will be open and close when the power is switched off or if
the mode is changed from DAY to NIGHT on terminal 4.
Another alternative to close the alarm relay is to switch DIP3
over to ON mode (D/N polarity).
The detectors are now back in DAY mode. If some detectors
have triggered an alarm during NIGHT mode, this will be indi-
cated by LED light. The alarm relay follows the setting of DIP1.
LED will flash on the detector that triggered the first alarm
and will shine firmly on the other alarming ones. When
switching from DAY to NIGHT – all the detectors are reset.
TECHNICAL DATA
Type (thickness) of protected glass
float (4 mm), laminated P2 (4 mm + 4 mm)
Size of protected glass
min 40×40 cm
Max range
9 m radius/165°
Zone 3 = 1–2 m
Range setting
Zone 2 = 2–4 m
Zone 1 = 4–9 m
Supply voltage
12 V DC (9 - 15 V DC)
Max. voltage ripple
2 Vpp at 12 V
Voltage monitoring
alarm at < 7 V ±0,5V
Current consumption quiescent/alarm state
26 mA/24 mA @ 12 V DC
Alarm output
relay
Alarm contact rating
50 mA, 50 V DC/peak AC, Rs ≤ 30 Ω
Tamper contact rating
50 mA/50 V DC/peak AC
Alarm indication
LED
Environmental class EN50130-5:2011, VdS 2110
Class I,
Operating temperature range
+5°C to +40°C
Operating humidity range
max. 93% RH
Housing material
ABS plastic white, brown or black color
Dimensions:
60x32x98 mm
Security grade
EN50131-2-7-1:2012, Grade 2, VdS Klasse B, SFS 1014-4
Approvals
VdS G104512 Class B, SBSC Alarm Class 2
We reserve the right to changes without notice