7845C
Cellular Control Channel Transceiver
Fast Track Setup
Pocket Guide
For ADEMCO and First Alert Controls
Now Pro*
Enabled!
*Programmerless
Registration Option
Страница 1: ...7845C Cellular Control Channel Transceiver Fast Track Setup Pocket Guide For ADEMCO and First Alert Controls Fast Track Setup Pocket Guide Now Pro Enabled Programmerless Registration Option ...
Страница 2: ...3 2 Register the Radio 3 2 Wire Radio to Control Panel 3 2 Test Alarm Delivery to Central Station 3 2 Wiring and Programming Guides By Panel Type 4 1 Vista 10 Vista 20 and Via 30 Non E2 Panels 4 1 Programming the Panel 4 1 Programming the 7845C with a 7720P Programming Tool or Using Pro 4 2 Wiring 4 2 VISTA 10SE VIA 30PSE FA142C FA145C and VISTA 10ADTG 4 3 Programming the Panel 4 3 Programming the...
Страница 3: ...ramming the 7845C with a 7720P Programming Tool or Using Pro 4 8 Wiring 4 8 VISTA 128B VISTA 128FB VISTA 32FB and FA1600 4 9 Programming the Panel 4 9 93 Menu Mode Programming 4 9 Device Programming 4 10 Programming the 7845C with a 7720P Programming Tool or Using Pro 4 11 Wiring 4 11 Non ADEMCO Panels 4 12 Programming the 7845C with a 7720P Programming Tool or Using Pro 4 12 Wiring 4 12 Appendix ...
Страница 4: ... job premises zip code to confirm that MicroBurst service is active in the local cellular network Check zip code at the AlarmNet web site WWW ALARMNET COM Or call the AlarmNet Technical Assistance Center at 800 222 6525 Obtain AlarmNet Account Numbers Contact your providing AlarmNet Central Station or your local data center to obtain all three of the necessary AlarmNet account numbers You will not...
Страница 5: ...anels ECP Mode VISTA with E2 only Contact ID communication Programmable Relay Emulation Mode Relay commands are sent via data connection ECP from the host VISTA panel to the 7845C does not require 4204 module 4229 Mode Allows the use of a 4229 zone expander as a seven zone input board Zone Mode Single Zone Input Pulsed Input Zone 1 Steady Input Zone 2 Section 2 Which Mode to Use CONTACT ID ADEMCO ...
Страница 6: ... Check to be sure that this location provides at least three steady bars on the signal strength meter 3 If signal strength is inadequate move radio and hold for another 10 seconds 4 Use 7825 OC outdoor antenna if specified or necessary 5 Even if original location provides three bars of signal strength test several other locations for better signal strength 6 Refer to Appendix I for tips on finding...
Страница 7: ...ck tamper switch or press SHIFT È to register 4 GreenL ED will go OFF when radio has successfully registered 30 seconds 5 Wire Radio to Control Panel 6 Refer to appropriate diagram in Section 4 7 Test Alarm Delivery to Central Station 8 Test according to your company s standard installation procedure ...
Страница 8: ... LIST Upon restore of ALL zones on this list relay action will STOP It need not be same list as used for START ZT ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 06 24 Hr Silent 01 Entry Exit 07 24 Hr Audible 03 Perimeter 08 24 Hr Aux 04 Interior Follower 09 Fire Trouble 05 Trouble Day Alarm Night 10 Interior w Delay Choices for System Operation are 20 Arming Stay 36 At Bell Time...
Страница 9: ...anels Or use PRO Mode Select 4204 by toggling the test tamper switch during power up so that MODE LED 1 is unlit and MODE 2 LED is lit The default device address will be 1 Wiring Connect as shown below For detailed information refer to the appropriate installation and setup guide Section 4 Wiring and Programming Guides by Panel Type cont V GND BATT 7845C ECP IN ECP OUT BLK RED GRN YEL TB2 TB1 BATT...
Страница 10: ... with a 7720P Programming Tool or Using Pro Using a 7720P enter programming mode Question 1 Mode Press the space key to scroll through the modes of operation ECP Press ENTER to select ECP Mode Question 2 Device Addr Enter the ECP device address of the radio For the VISTA 10 Family this must be address 3 Or use PRO Mode Select ECP by toggling the test tamper switch during power up so that MODE LED ...
Страница 11: ...ogramming mode Question 1 Mode Press the space key to scroll through the modes of operation ECP Press ENTER to select ECP Mode Question 2 Device Addr Enter the ECP device address of the radio For the FA147C this must be address 3 Or use PRO Mode Select ECP by toggling the test tamper switch dur ing power up so that MODE LED 1 is lit and MODE 2 LED is unlit The default device address will be 3 Wiri...
Страница 12: ...l or Using Pro Using a 7720P enter programming mode Question 1 Mode Press the space key to scroll through the modes of operation ECP Press ENTER to select ECP Mode Question 2 Device Addr Enter the ECP device address of the radio For the VISTA 15 Family this must be address 3 Or use PRO Mode Select ECP by toggling the test tamper switch during power up so that MODE LED 1 is lit and MODE 2 LED is un...
Страница 13: ...Using Pro Using a 7720P enter programming mode Question 1 Mode Press the space key to scroll through the modes of operation ECP Press ENTER to select ECP Mode Question 2 Device Addr Enter the ECP device address of the radio For the VISTA 20 Family this must be address 3 Or use PRO Mode Select ECP by toggling the test tamper switch during power up so that MODE LED 1 is lit and MODE 2 LED is unlit T...
Страница 14: ...inue RELAY PROG 1 Select 1 to enter relay programming 1 YES 0 NO ENTER RELAY NO Enter the relay output device identifica tion number 01 16 A maximum of 8 outputs can be used with the 7845C 00 QUIT 01 Using the information below program each relay output used with START STOP and EVENT parameters Relay output will correspond with the same Zone on the radio Where A RELAY ACTION 0 No Response 1 Close ...
Страница 15: ...y Or at Disarming whichever occurs earlier Programming the 7845C with a 7720P Programming Tool or Using Pro Using a 7720P enter programming mode Question 1 Mode Press the space key to scroll through the modes of operation 4204 Press ENTER to select 4204 Mode Question 2 Device Addr Enter the ECP device address of the radio This must be address 1 for all panels Or use PRO Mode Select 4204 by togglin...
Страница 16: ...nu Mode Programming ZONE PROG Press 1 to enter ZONE PROGRAMMING mode 1 Yes 0 No The following screens will appear Press to display the next screen Press to display a previous screen ENTER ZN NO Enter the 3 digit zone number that you wish to program As an ECP device the 7845C must be in the 800 range 000 QUIT 803E Zone 803 is shown here Press to continue 803ZT P RC INL A display will appear showing...
Страница 17: ...formation about report codes and report code formats Press to continue Device Programming From the prompt ZONE PROG press 0 repeatedly to display DEVICE PROG DEVICE PROG 1 Press 1 to enter Device Programming 1 YES 0 NO DEVICE The device address identifies the ADDRESS device to the control Enter the 2 digit 01 31 00 QUIT device address number to match the device s physical address setting 01 30 Pre...
Страница 18: ... panels see the control panel s installation and setup guide Or use PRO Mode Select ECP by toggling the test tamper switch during power up so that MODE LED 1 is lit and MODE 2 LED is unlit The default device address will be 3 Wiring Connect as shown below For detailed information refer to the appropriate installation and setup guide Section 4 Wiring and Programming Guides by Panel Type cont V GND ...
Страница 19: ... Connect as shown below For detailed information refer to the appropriate manual EOL resisters on the 4229 may vary from control panel to control panel Section 4 Wiring and Programming Guides by Panel Type cont V GND BATT 7845C ECP IN ECP OUT GRN YEL TB2 TB1 4 3 2 1 TB2 DATA IN 12V GND DATA OUT 4229 1 2 3 4 5 6 7 8 9 10 11 12 TB1 2 x 2K EOLR 1K see note 1K 1K 1K 1K 1K 1K Z Z Z Z Z Z C NO NC EOLR f...
Страница 20: ...sements AVOID OBSTACLES Always mount on exterior walls near windows if possible Keep away from large metal objects such as filing cabinets refrigerators water heaters furnaces etc Stay away from heavy concrete walls Remember to consider metal roofs siding and wall studs as possible problems AVOID INTERFERENCE Never mount the radio inside the control panel can Keep away from other radio devices inc...
Страница 21: ...r radio Incorrect Carrier Select Option Current limit Y with a low or no battery Check web site www ADEMCO com alarmnet or AlarmNet TAC 1 800 222 6525 to determine availability Run 7845C with a charged battery outside of the building Run 7845C with a charged battery outside of the building If A only or B only selected make sure this is correct for your area Connect a fully charged battery to the 7...
Страница 22: ...grity 7845C powered but will not transmit S command from a 7720P shows a C under the battery status Current limit Y with a low or no battery Connect a fully charged battery to the 7845C Low battery alarm received If this is a new install the battery was probably not charged If this is an existing installation and DC power was lost or inadequate Environment is too hot or too cold Old battery on old...
Страница 23: ... or on all the time Poor cellular cov erage Antenna improper ly installed Antenna located near metallic object steel studs wire lath plaster walls etc Installation site unsuitable for indoor antenna Current limit Y with a low or no battery Recheck installation per the selecting a radio installation site paragraph in Section 4 Move the 7845C until RSSI level and transmission suc cess rates are acce...
Страница 24: ...with them Site testing should be done in the worst case configuration i e rollup gate or garage door down etc Nothing can be done for this problem and although rare It can happen Failure to supervise Alarm with no restores Radio Fault with no restore 7845C has failed or lost power Radio coverage has faded due to poor initial installa tion or new obstructions at the installation Check 7845C for pro...
Страница 25: ... conditions Certain control panels will not send alarms to the 7845C if certain radio faults exist such as tamper or out of coverage indications Make sure the cover is on the 7845C and that it has cellular coverage and is registered red and green LEDs both off Programmable Relay Mode Problems Intermittent Check 8xx indicated on Keypad of high end control panel VISTA 128 40 or slow blinking red sta...
Страница 26: ...There is a wiring problem between the 7845C and the control panel If 4229 mode the two 2K resistors might not be installed correctly Check the wiring Make sure that ECP IN ECP OUT and GND are all correctly con nected Check that the two 2K resis tors are connected between ECP IN and GND and ECP OUT and GND General Problems 7845C will not register Error in programming Poor coverage Verify that City ...
Страница 27: ...165 Eileen Way Syosset NY 11791 Copyright c 2000 PITTWAY CORPORATION K4426FTV1 10 00 ...