BASIC WIRING: PDK3000
Interfacing to an access control system to allow code access in addition to keyfob access. Auxiliary Relay is not connected.
Wire nut connections are represented by a
wire with a spherical end, intersecting another
wire, as shown in the
following illustration:
=
Required Programming
Set appropriate Pass Time in Passage Options (3,10
or 15 seconds). Default Pass Time = 3 sec.
Operation
•
The PDK3000 interrupts Power Mag Power upon a
successful code (or Prox) entry, initiating Pass Time.
•
The Remote Input (as shown) may be used as a re-
quest to exit button.
POWER SUPPLY OPTIONS
Emergency Exit
Switch
Emergency Exit
Switch
SUPPLY
BLACK
PDK3000
Power Input
PURP
LE
BLUE
N/C
BLACK
Com
Entry
Relay
Output
Remote
Release
Output
Tamper Output
Mounted to
Housing
Auxiliary
Relay
Output
N/O
GRAY
ORANGE (N/O)
BLACK (COM)
WHITE (N/C)
N/O Push
Button
Switch
N/C
Alarm System
Zone Programmed
for 24-Hour Alarm
1. Magnetic Lock
2. Electric Strike
3. Solenoid Device
BLA
C
K
RE
D
1. Mag Lock
2. Electric Strike
3. Solenoid
4. Light
5. Siren
6. Video Recorder
WHITE
WHITE
Simplified Power Supply Option:
Transformer 12 to 24 VAC or DC
Recommended Supply Option:
Battery Backup 12 to 24V AC or DC
WARNING
In all cases, be sure to
allow for emergency exit
during a fire or AC power
failure.
Local jurisdictions may
require use of an access
power supply with battery
backup, with provisions
for timed emergency exit.
IMPORTANT
Refer to page 11 for voltage
specifications.
Do NOT
connect
the Auxiliary Relay Output to
more than 24 volts AC or DC.
Supplied
Transient
Protection