32
User Number
(1-300)
User Code
(3-6 digits)
User Name
1
2
3
4
Group
Association
For a complete list of user codes, obtain a printout from either the remote printer (Program Function 56) or using the DL-WINDOWS Software.
Note:
Страница 1: ...005E 03 15 AL DTM DATA TRANSFER MODULE AL IR1 PRINTER 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 or visit us at http tech na...
Страница 2: ...L3500 DL3500EX Features a real time clock calendar that automatically adjusts for Daylight Sav ing Time and allows for automated programming of events Features three methods of programming 1 all featu...
Страница 3: ...nable Disable Groups see page 17 Four Quick Schedules contains 4 most common schedules see page 26 Real time clock and calendar see page 19 Programmable Timeout Functions see page 18 User Access Metho...
Страница 4: ...e AL PCI cable features a 2 pin banana plug connector which is polarity sensitive the TAB marked GND side must be plugged into the lock s black left terminal Supported Products Data Transfer Module AL...
Страница 5: ...steps required to get your lock to start working To begin programming you must first enter something called Program Mode What is Program Mode With software changes are made using the keypad The softwa...
Страница 6: ...ority a Programming Level as to their ability to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming tasks a User is allowed to perform T...
Страница 7: ...ws access for one time and then the Us er 300 User Code becomes disabled For example you wish to allow one time access to a tempo rary worker Simply enter the User 297 User Code into the lock keypad L...
Страница 8: ...L Series locks can hold hundreds of Users in its programming memory and each User is associated with a User Number see definition of User Number in the previous Terminology section and therefore a spe...
Страница 9: ...error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All program sequences are followed by the key 2 short beeps indicate a successful program sequence Enabling...
Страница 10: ...ram in DL Windows and transfer the program from your computer to an AL DTM via an AL PCI cable then transfer the program from the AL DTM to the lock s via a double ended mini banana plug The hand held...
Страница 11: ...ery pack 2 With battery power disconnected press and hold down for 10 seconds to ensure discharge of all ca pacitors 3 Re install the battery pack lock will sound 3 short beeps If beeps are not heard...
Страница 12: ...w that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly below and program various functions Note...
Страница 13: ...urrently open the lock If the lock does not open the anticipated Master Code can be used as the new Master Code if the lock opens the anticipated Master Code already exists in the lock as a User Code...
Страница 14: ...page 20 Programming Functions Overview Function 48 Enable Passage Mode See page 21 Function 49 Disable Passage Mode See page 21 Function 50 Return Lock to Normal Passage Mode Schedule See page 21 Func...
Страница 15: ...ock Design Overview on page 5 for more information about Master Codes 3 M USERS Lock Defaults for DL3500 DL3500EX See page 8 Users added will default to a Group Association and a Program Level Ability...
Страница 16: ...g Program Mode and pressing 5 157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is...
Страница 17: ...emain 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overr...
Страница 18: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...
Страница 19: ...d ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...
Страница 20: ...nctions are not cumulative this means for example if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Func...
Страница 21: ...ode is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4...
Страница 22: ...Figure 2 above To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDO...
Страница 23: ...ttempts is reduced by half every time the keypad is locked out without a successful code entry default is 6 attempts The attempt count is reset each time a valid code is entered Function 61 determines...
Страница 24: ...Code is entered followed by a valid User Code the relay will close for 2 seconds Notes The Ambush Code defaults to 99 An error will sound if you try to program a new User Code starting with the Ambus...
Страница 25: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...
Страница 26: ...Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Do not use this feature in Residency mode Scheduled P...
Страница 27: ...ay 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 R...
Страница 28: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For addi tional information see Group 1 Activated Features on page 29 For day en...
Страница 29: ...tion See To Disarm a Burglary Control Panel on page 28 If a Group 1 User does not enter their User Code during the specified window Functions 90 91 remain inactive Function 92 and 93 allow for a windo...
Страница 30: ...of the alarm panel Functions 92 93 Use Function 92 and 93 see page 28 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1...
Страница 31: ...put switch closed and Function 65 Remote Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow Access Granted 6 Gr...
Страница 32: ...umber 1 300 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...
Страница 33: ...programmed Up to only 150 using AL DTM For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter...
Страница 34: ...ser Code Allows only one entry then needs to be re enabled by the User 297 User Code to regain access SUPERVISOR CODE User Codes assigned to Users 7 8 and 9 Can only program day to day operation USER...
Страница 35: ...LOG See AUDIT TRAIL MANAGER See CODE MANAGER CODE MASTER See CODE MASTER CODE PASSAGE Allow anyone to pass through the door without USER CODES door is unlocked PRINTER A printout device such as an in...
Страница 36: ...lvents or other chemi cals This warranty contains the entire warranty It is the sole warranty and any prior agreements or representations whether oral or written are either merged herein or are expres...