be denied access on a regular basis to simplify the lockout
procedure.
User Codes must consist of the same number of digits as
the Master Code. To program any User Code:
1. Enter the Master Code or Management Code. A beep
will sound and the lock will unlock.
2. From Table 1, enter the Program Address for the
selected user.
3. Enter the User Code; six beeps will sound.
4. Test the User Code.
Note:
Note: If several User Codes will be programmed at one
time, it is not necessary to re-enter the Master or Manage-
ment Code for each, so long as the lock is not allowed to
relock. Therefore, after the six beeps sound (step 3, above)
repeat steps 2 and 3 as necessary, then test all codes when
done.
Service Code
Service Code
The Service Code is a one-time User Code for cleaning
crews, servicers, etc., that erases itself immediately after
use. It is programmed as any User Code, with the Program
Address
AL-3-AL
. If programmed, the Service Code re-
places User Code 15 (Bank 3, User 5).
PROGRAMMING SPECIAL FUNCTIONS
PROGRAMMING SPECIAL FUNCTIONS
Lockouts
Lockouts
Any single user, any bank of users, or all users may be
prevented from entry.
User Lockout.
User Lockout. To temporarily disable any single user’s
entry code,
1. Enter the Master Code or Management Code.
2. From Table 1, enter the user’s Program Address.
3. Wait for the lock to relock.
To re-enable the code, repeat the procedure.
Group Lockout.
Group Lockout. To temporarily disable all user entry
codes of one or more banks,
1. Enter the Master Code or Management Code.
2. From Table 2, enter the Bank Disable Address(es).
3. Wait for the lock to relock.
To re-enable the code(s), repeat the procedure, replacing
the Disable Address in Step 2 with the Enable Address.
Note:
Note: Re-enabling a group lockout does not re-enable a
single-user lockout of that group (see
User Lockout
).
Unlock Time
Unlock Time
This is the amount of time that the lock stays open after
a valid code is entered. The factory-programmed time is 5
seconds, however this time may be increased to up to 20
seconds as follows.
1. Enter the Master Code or Management Code.
2. Enter Address [AL] [4] [5] [AL].
3. From Table 3, enter the desired unlock time.
Note:
Note: To conserve battery power, keep unlock time as
short as possible.
Passage
Passage
Programming the Passage Function will maintain the
DL2700 unlocked (no code required for entry) until repro-
grammed. To set the Passage Function, enter the Master
Code, then Address [AL] [4] [AL]. To relock, enter the
Master Code, then Address [AL] [5] [AL].
OTHER IMPORTANT INFORMATION
OTHER IMPORTANT INFORMATION
Antitamper Protection
Antitamper Protection
If three invalid codes are entered in succession, the unit
will shut down for approximately 20 seconds to prevent
code tampering. Two short beeps will sound when the lock
has been reactivated.
Battery Replacement
Battery Replacement
A 5-second dual tone (4 seconds high; 1 second low)
when any key is pressed indicates that the batteries are
weak. The DL2700 uses 5 AA-size1.5-volt alkaline batteries.
The lock will function with weak batteries, however be sure
to replace the batteries as soon as possible.
Remove the screw at the bottom of the interior lock
housing and remove the cover. Replace all 5 batteries
quickly ---- within about 2 minutes ---- to avoid losing the
memorized codes.
Do not press any buttons while replac-
ing the batteries!
Replace the battery cover, then test the
lock. Note:
Note: To immediately erase all codes, remove the
batteries and press any button.
Should battery power fail and all codes be erased, open
the door using the key and replace the batteries. Repro-
gram all codes starting with the original factory Master
Code (
1-2-3-4-5
).
Remote Release
Remote Release
Provisions for unlocking the DL2700 from a remote loca-
tion, overriding all codes, using an external momentary-
contact switch.
BANK
BANK
DISABLE ADDRESS
DISABLE ADDRESS
ENABLE ADDRESS
ENABLE ADDRESS
1
AL-5-1-AL
AL-4-1-AL
2
AL-5-2-AL
AL-4-2-AL
3
AL-5-3-AL
AL-4-3-AL
1--3
AL-5-5-AL
AL-4-4-AL
Table 2. Bank Disable and Enable Addresses.
Table 2. Bank Disable and Enable Addresses.
ENTRY
ENTRY
TIME
TIME
1
5 SEC.
2
10 SEC.
3
15 SEC.
4
20 SEC.
Table 3. Unlock Times (times approximate).
Table 3. Unlock Times (times approximate).
BANK 1
BANK 1
PROGRAM
PROGRAM
ADDRESS
ADDRESS BANK 2
BANK 2
PROGRAM
PROGRAM
ADDRESS
ADDRESS BANK 3
BANK 3
PROGRAM
PROGRAM
ADDRESS
ADDRESS
User 1
AL-1-1-AL
User 1
AL-2-1-AL
User 1
AL-3-1-AL
User 2
AL-1-2-AL
User 2
AL-2-2-AL
User 2
AL-3-2-AL
User 3
AL-1-3-AL
User 3
AL-2-3-AL
User 3
AL-3-3-AL
User 4
AL-1-4-AL
User 4
AL-2-4-AL
User 4
AL-3-4-AL
User 5
AL-1-5-AL
User 5
AL-2-5-AL
User 5*
AL-3-5-AL
*May be programmed as Service Code (AL-3-AL). See Service Code
Service Code.
Table 1. User Program Addresses.
Table 1. User Program Addresses.