3
•
Orange LED lights - sounder beeps twice.
2.
Press
34#
•
Green LED blinks once - sounder beeps once.
3.
Press the 3-digit User Number
associated with the
User Code you wish to delete and press
#*
.
•
Green LED lights / sounder beeps for 1 second indi-
cating the User Code was deleted successfully.
Exit Program Mode
When you finish programming and wish to put the keypad
into use, you exit Program Mode to enter "Normal Mode"
as follows:
•
Exit Program Mode
: Press
*
.
The orange LED turns off, the sounder beeps twice and
the red LED lights.
Note:
The keypad will automatically
exit Program Mode if no keys are pressed within 120 sec-
onds (2 minutes).
Test the Keypad
Be sure to test all User Codes. Keep in mind the follow-
ing:
•
Valid User Codes must be followed by the star (
*
) key
•
Master Code and User Codes must all be the same
length
•
By default, a valid User Code always activates Output 1
unless Output selection is changed
ALL PROGRAMMING FUNCTIONS
Your keypad is designed to support several options and
functions. Using the keypad, you can select the features
you wish to activate, such as if the keypad sounder should
be disabled or enabled or you wish to change the code
length from 4 to 6 digits..
Each function is organized below by its function number,
which is the first two digits pressed into the keypad when
programming. To program, first enter Program Mode as
follows:
•
Enter Program Mode
: Press
55#
[
Master Code
]
*
.
When you finish programming and wish to put the key-
pad into use, exit Program Mode to enter "Normal Mode"
as follows:
•
Exit Program Mode
: Press
*
.
Note:
The audible sounder and visual LED indicators
are displayed in the text below as follows:
[
O2
] = Orange LED lights and sounder beeps twice
[
G1
] = Green LED lights and sounder beeps once
[
R2
] = Red LED lights and sounder beeps twice
Note:
Every duration field is a two digit field. Master code
is strictly reserved for entering Program Mode and cannot
be used to activate an Output.
21 Output 1 Activation Duration
Program time from 01 to 99 seconds. Program 00 to
select "latch mode" where output remains activated by
the entry of a valid User Code (until deactivated by the
entry of a second valid User Code).
Note:
By default, a
valid User Code always activates Output 1 unless Out-
put selection is changed.
Press:
21#
[
G1
] ___ ___
#*
[
G1
].
22 Output 2 Activation Duration
Program time from 01 to 99 seconds. Program 00 to
select "latch mode" where output remains activated by
the entry of a valid User Code (until deactivated by the
entry of a second valid User Code).
Press:
22#
[
G1
] ___ ___
#*
[
G1
].
23 Output 3 Activation Duration
Program time from 01 to 99 seconds. Program 00 to
select "latch mode" where output remains activated by
the entry of a valid User Code (until deactivated by the
entry of a second valid User Code).
Press:
23#
[
G1
] ___ ___
#*
[
G1
].
24 Illuminated Keypad
Turns illuminated keypad ON, OFF or allows the illumi-
nation to remain ON for a specified duration after
keypress (the duration is programmed by Function 25).
Always ON Press:
24#
[
G1
]
0#*
[
G1
].
Always OFF Press:
24#
[
G1
]
1#*
[
G1
] and
do NOT program Function 25.
Timed ON Press:
24#
[
G1
]
1#*
[
G1
] and
program Function 25 with two-digit time duration.
25 Illuminated Keypad Duration
See function 24. Program time from 10 to 99 seconds.
Press:
25#
[
G1
] ___ ___
#*
[
G1
].
30 Code Length
Changes the number of required digits in all new User
Codes and the existing Master Code. 3-6 digits are al-
lowed, thus valid entries are "3", "4", "5" or "6". The fac-
tory default Code Length is 4.
WARNING:
When the Code Length is changed, all ex-
isting User Codes and the Master Code become invalid.
Because the Master Code and all User Codes must
al-
ways
be the same number of digits in length, if you
change the Code Length with Function 30 you MUST
remain in Program Mode and change the Master Code
to conform to the new programmed "Code Length".
Press:
30#
[
G1
] ___
#*
[
G1
].
31 Modify Master Code
Changes existing Master Code.
Note:
The Master
Code and all User Codes must
always
be the same
number of digits in length. If changing the number of
digits in the Master Code, you must first change the
Code Length via Function 30 (to accommodate the new