2.   

Press 

32#

  

Green LED blinks once - sounder beeps once. 

3.   

Press new 3-digit User Number 

and press 

#

.   

Green LED blinks once - sounder beeps once. 

4.   

Press new 4-digit User Code 

and press 

#

Green LED blinks once - sounder beeps once. 

5.   

Re-press new 4-digit User Code 

and press 

#*

Green LED lights / sounder beeps for 1 second indi-
cating the User Code was added successfully.   

 

Delete a User Code 

1.   

If not in already, enter Program Mode

Orange LED lights - sounder beeps twice. 

2.   

Press 

34#

  

Green LED blinks once - sounder beeps once. 

3.   

Press the 3-digit User Number 

associated with the 

User Code you wish to delete and press 

#*

.   

Green LED lights / sounder beeps for 1 second indi-
cating the User Code was deleted successfully.   

 

Exit Program Mode 

When you finish programming and wish to put the keypad 
into use, you exit Program Mode to enter "Normal Mode" 
as follows: 

 

Exit Program Mode

:  Press 

*

 

The orange LED turns off, the sounder beeps twice and 
the red LED lights.  

Note:

  The keypad will automatically 

exit Program Mode if no keys are pressed within 120 sec-
onds (2 minutes).   
 

Test the Keypad 

Be sure to test all User Codes.  Keep in mind the follow-
ing: 

Valid User Codes must be followed by the star (

*

) key 

Master Code and User Codes must all be the same 
length 

By default, a valid User Code always activates Output 1 
unless Output selection is changed 

 
 

ALL PROGRAMMING FUNCTIONS 

 

Your keypad is designed to support several options and 
functions.  Using the keypad, you can select the features 
you wish to activate, such as if the keypad sounder 
should be disabled or enabled or you wish to change the 
code length from 4 to 6 digits.. 

 

Each function is organized below by its function number, 
which is the first two digits pressed into the keypad when 
programming.  To program, first enter Program Mode as 
follows: 

 

Enter Program Mode

:  Press 

55#

  [

Master Code

*

 

When you finish programming and wish to put the key-
pad into use, exit Program Mode to enter "Normal Mode" 
as follows: 

 

Exit Program Mode

:  Press 

*

 

Note: 

 The audible sounder and visual LED indicators 

are displayed in the text below as follows: 

 

[

O2

] = Orange LED lights and sounder beeps twice 

[

G1

] = Green LED lights and sounder beeps once 

[

R2

] = Red LED lights and sounder beeps twice 

 

Note:

  Every duration field is a two digit field.  Master code 

is strictly reserved for entering Program Mode and cannot 
be used to activate an Output.   

 

21  Output 1 Activation Duration  

Program time from 01 to 99 seconds.  Program 00 to 
select "latch mode" where output remains activated by 
the entry of a valid User Code (until deactivated by the 
entry of a second valid User Code).  

Note:

  By default, a 

valid User Code always activates Output 1 unless Out-
put selection is changed. 

 

Press:

  

21#

 [

G1

] ___ ___ 

#*

 [

G1

]. 

 

22  Output 2 Activation Duration  

Program time from 01 to 99 seconds.  Program 00 to 
select "latch mode" where output remains activated by 
the entry of a valid User Code (until deactivated by the 
entry of a second valid User Code). 

 

Press:

  

22#

 [

G1

] ___ ___ 

#*

 [

G1

]. 

 

23  Output 3 Activation Duration  

Program time from 01 to 99 seconds.  Program 00 to 
select "latch mode" where output remains activated by 
the entry of a valid User Code (until deactivated by the 
entry of a second valid User Code). 

 

Press:

  

23#

 [

G1

] ___ ___ 

#*

 [

G1

]. 

 

30  Code Length  

Changes the number of required digits in all new User 
Codes and the existing Master Code.  3-6 digits are al-
lowed, thus valid entries are "3", "4", "5" or "6".  The fac-
tory default Code Length is 4. 

 

WARNING: 

 When the Code Length is changed, all ex-

isting User Codes and the Master Code become invalid.  
Because the Master Code and all User Codes must 

al-

ways 

be the same number of digits in length, if you 

change the Code Length with Function 30 you MUST 
remain in Program Mode and change the Master Code 
to conform to the new programmed "Code Length".   

 

Press:

  

30#

 [

G1

] ___ 

#*

 [

G1

]. 

 

31  Modify Master Code 

Changes existing Master Code.  

Note:

  The Master 

Code and all User Codes must 

always 

be the same 

number of digits in length.  If changing the number of dig-
its in the Master Code, you must first change the Code 
Length via Function 30 (to accommodate the new num-
ber of digits in the new Master Code) and--without exiting 
Program Mode--change the Master Code via Function 
31. 

 

Press:

   

31#

  [

G1

] (

new MC

#

  [

G1

] (

new MC

#*

 

[

G1

]. 

 

Содержание A-100

Страница 1: ...d pro grammed Exit Program Mode to put the keypad with its new programming into use SPECIFICATIONS 12 to 24VDC polarized or 12 to 24VAC voltage input Output 1 5A 250VAC relay Output 2 3A 125VAC relay Output 3 250mA open collector Capacity of 150 User Codes of 3 to 6 digits Output activation duration programmable from 01 99 sec onds program 00 to select toggle mode All programming stored in non vol...

Страница 2: ...code that allows you to enter Program Mode But since all keypads leave the factory with this same Master Code the factory Master Code is therefore not very secret and should be changed to your own personal Master Code This way only YOU can enter Program Mode and make changes to the keypad programming Change Factory Master Code Although the factory Master Code can be changed at any time for highest...

Страница 3: ...sual LED indicators are displayed in the text below as follows O2 Orange LED lights and sounder beeps twice G1 Green LED lights and sounder beeps once R2 Red LED lights and sounder beeps twice Note Every duration field is a two digit field Master code is strictly reserved for entering Program Mode and cannot be used to activate an Output 21 Output 1 Activation Duration Program time from 01 to 99 s...

Страница 4: ...puts 1 and 3 press 02 to activate Output 2 only press 10 to activate Output 1 only etc Note If Function 70 Output 3 Activates on First Keypress is enabled Output 3 cannot be included in the choices offered by Function 52 Note The value in Output 2 timer value from 01 to 99 seconds is the duration of relay 2 activation when the door bell button is momentarily pressed If the door bell activation mus...

Страница 5: ...t Open Collector Output Normally Open Relay 1 Common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 S2 S1 Tamper SW Output Tamper SW Output A 100 Keypad 12V or 24V AC DC Input NO C2 C1 NC NC NO M P1 OC Ground Request to Exit Input Request to Exit Input Open Collector Output Normally Open Relay 1 Common Relay 1 Normally Closed Relay 1 Normally Open Rela...

Страница 6: ...C G1 newMC G1 32 Add or Edit a User Code Press 32 G1 User Number G1 User Code G1 re enter User Code G1 33 Add or Edit a User Code with Output 1 Duration Press 33 G1 time 01 99 G1 User Number G1 User Code G1 re enter User Code G1 34 Delete User Code Press 34 G1 User Number G1 52 Add or Edit a User Code with Output Activation Press 52 G1 2 digits G1 User Number G1 User Code G1 re enter User Code G1 ...

Страница 7: ...7 MOUNTING TEMPLATE The A 100 is designed to be installed in a single gang box The mounting screws are 3 apart 3 ...

Страница 8: ...r authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the produc...

Отзывы: