ALADIN ALADIN PRO Скачать руководство пользователя страница 3

Содержание ALADIN PRO

Страница 1: ......

Страница 2: ...battery I 11 c...

Страница 3: ...ORAGE IN A DAMP ENVIRONMENT CAN GREATlY REDUCE THE BATTERY LIFE THIS INSTRUMENT DOES NOT REPlACE SOUND DIVING INSTRUCTION AND DOES NOT EXEMPT THE OWNER FROM DIVING RESPONSIBLY AND REASONABLY READ THE...

Страница 4: ...ive as long as the ascent is conducted at a constant rate of 10 m min 2 3 The ALADIN PRO isthe first dive computer to take into account the decreased rate of release of nitrogen from the diver s tissu...

Страница 5: ...quirements second to none in the field of diving The data used to give the decompression limit and decompression take into account the time elapsed prior to diving and the actual diving profile 10 mul...

Страница 6: ...nt have remained at the same altitude and have not dived for the pre ceeding 24 hour period The AIADIN PRO has no moving parts such as switches making it safe maintenance free I and user friendly The...

Страница 7: ...of more than 150 m within the 35 min period prior to diving as the instrument requires this 35 min period to assimulate the altitude information Should a dive become necessary within this 35 min peri...

Страница 8: ...f the water 2 3 Maximum depth Maximum depth is displayed at position 21 max depth whenever it is higher than the current depth In order to avoid a continually changing display when at the maximum I de...

Страница 9: ...s that no decompression stops will be required if the dive continues for another 24 minutes Ifig 41 The no decompression limit is continuously adjusted to the current depth and dive time When itshows...

Страница 10: ...Decompression should be carried out at the depths indicated Decompressing at a shallower depth is forbidden Isee section 2 9 1 Should heavy seas require it decompres sion can be carried out at a deep...

Страница 11: ...ins then the display will show 99 2 8 Ascent rate alarm The recommended ascent rate is 10 ml min If the ascent rate exceeds 12 ml min a black upward pointing arrow carrying SLOW will appear at positio...

Страница 12: ...depth indicated by the instrument While the DECO STOP display is flashing the instrument suspends calculation of the tissue desaturation the diver continues the ascent the DECOSTOP display will contin...

Страница 13: ...ing The data shown on the ALADIN PRO during the period of suspension I should be copied out and communicated to any physician who rnov require ta odminister _ a subsequent therapeutic recompression Th...

Страница 14: ...rface mode is indicated by the display 01 SURFACE at position 9 together with the current desaturation time in hours and minutes e g 8h 29 Ilig 121 The desotu ration time will continue to be computed...

Страница 15: ...est when planning a dive using dive tables is displayed in the planning mode OIVEPLAN Isee section 2 11 belowl Point 3 II the period during which flying islorbidden is longer than 9 hours then the tim...

Страница 16: ...mode this display is omitted This is followed by the display of no decompression time limits for every 3 m increment of depth from 9 m to 42 rn for the current altitude sector Ifig 141 Each limit is...

Страница 17: ...r displaying the 9th dive the instrument will leave LOG BOOK mode This will also happen after 3 mins if the logbook contacts are not touched When contact is maintained all dives in the logbook are dis...

Страница 18: ...mate altitude levels for the 4 sectors are as fallows Sector 0 0 1000 m a s theoretical limit 800 m Sector 1 600 1900 m a s theoretical limit 1650 m Sector 2 1400 2800 m a s theoretical limit 2550 m S...

Страница 19: ...be taken into considera tion for professional diving 32 33 2 14 Low battery alarm e low battery warning LOW BAT at position 12indicates that the battery should be doced Even though the ALADIN PRO wil...

Страница 20: ...e original packing I After a dive avoid putting the ALADIN PRO into a wet dive bag so that it may dry properly Follow the instructions for baitery replacement 12 141 34 35 4 Warning The ALADIN PRO doe...

Страница 21: ...the fastest tissuewhich is not sufficiently desaturated Isection 6 fig 16 page 291 Before delivery AlADIN PRO is tested in a pressure chamber These test dives are recorded in the logbook The colours a...

Страница 22: ...nts For an average dive time of 45 mins and a typical desaluration time of 10 hours after each dive CNS Central Nervous System brain spinal cordi 38 7 Warranty following conditions apply to the ALADIN...

Страница 23: ...iability The buyer and user oftheALADIN PRO relieves the manufacturer and vendor from ailliabil ity for damage incurred when and after diving with the instrument October 1988I UWATEC AG 5705 Haliwil S...

Страница 24: ......

Отзывы: