AL-KO HYDROOPT M Скачать руководство пользователя страница 2

Translation of the original installation and operating instructions

2

AL-KO HYDROOPT

®

Legal

AL-KO THERM GmbH 

Hauptstraße 248 - 250 

89343 Jettingen-Scheppach 

Germany 

Telephone: +49 8225 39 - 0 

Fax: 

+49 8225 39 - 2113 

E-mail: [email protected]

Revision history

Version

Description

Date

1.0

Initial release

27/04/2020

Содержание HYDROOPT M

Страница 1: ...TRANSLATION OF THE ORIGINAL INSTALLATION AND OPERATING INSTRUCTIONS HYDROOPT M CENTRAL VENTILATION AND AIR CONDITIONING UNITS EN...

Страница 2: ...instructions 2 AL KO HYDROOPT Legal AL KO THERM GmbH Hauptstra e 248 250 89343 Jettingen Scheppach Germany Telephone 49 8225 39 0 Fax 49 8225 39 2113 E mail klima technik al ko de Revision history Ve...

Страница 3: ...ection 12 2 4 1 Cabling to the customer s control technology 12 2 4 2 Bus model assembly option 13 3 Commissioning 14 3 1 General information 14 3 2 Requirements 14 3 3 Procedure for commissioning 14...

Страница 4: ...n amount is continuously recorded and can be used together with the temperature measurement for heat quantity metering The decision whether heat recovery is possible and how much heat should be recove...

Страница 5: ...m this 1 3 Residual dangers The system may present a danger if it is not operated by trained personnel and or is not used according to its designated use Residual dangers are potential dangers that ar...

Страница 6: ...equired quantity of brine being circulated see drawing System pressure 4 to 6 bar Supply voltage 3 Ph 400 V 50 Hz Fuse max 20 A slow blow The maximum customer side back up fuse is specified on the enc...

Страница 7: ...l units Type Dimension Flow rate m3 h Length mm Width mm Height mm Weight kg 2 DN 32 0 5 1 9 1330 695 1680 170 5 DN 40 2 0 4 9 1330 695 1680 178 10 DN 50 5 0 9 9 1330 695 1680 205 15 DN 65 10 0 14 9 1...

Страница 8: ...demand 0 10 V Heat up mode demand disconnect all exhaust air exchangers Operating feedback message digital out Error alarm A Error alarm B OPTIONAL bus connection 1 Switch cabinet 9 Expansion tank ins...

Страница 9: ...mode demand disconnect all exhaust air exchangers Operating feedback message digital out Error alarm A Error alarm B OPTIONAL bus connection 1 Switch cabinet 9 Expansion tank installation on the intak...

Страница 10: ...temperature changes must be prevented during storage This is especially harmful if moisture is able to form condensation Damage that results from improper packaging storage and transport are at the e...

Страница 11: ...tup Important Components that come loose during transport can lead to faults or damage The station must be checked for transport damage upon delivery The condition of the ground must be taken into acc...

Страница 12: ...r other materials Check fuses clamping connections contactors and circuit boards to ensure that they are seated firmly Re secure any loose components Protect the pump motor against overload The electr...

Страница 13: ...modules are optionally available for this Modbus BACnet TCP IP The figure shows the Climatix BACnet POL908 00 IP module STD It is connected to the Climatix control system via the internal communicatio...

Страница 14: ...ctional arrow is marked on the pump The analogue pressure monitor attached upstream of the pump protects the pump from running dry due to lost brine The switching threshold was set in the factory to a...

Страница 15: ...fans be put into operation and the enable given for the closed cycle system After the enable contact an analogue request signal 0 10 Volt is required by the customer for operation of the closed cycle...

Страница 16: ...WN button This button can be used to scroll down in the current menu or to reduce the setting value 6 ENTER button This button can be used to confirm a new setting and activate the new setting value 7...

Страница 17: ...of time If the fluid volume is implausible the system is switched off with an A alarm Pump 1 B Pump frequency converter has triggered System check required Pump 2 B Pump frequency converter has trigg...

Страница 18: ...ed and system information retrieved The displayed language can be changed with the service password in the main menu System information e g temperatures and brine air volumes can be viewed in the main...

Страница 19: ...d from the factory as follows Level Default password Description User 1000 Level for the operator to select the setpoint source and alarm acknowledgement Service Level for service technicians with man...

Страница 20: ...nder Settings the service technician can adjust the system parameters in the service level Always set a valid date or the correct time in order to obtain all functions 4 4 3 Commissioning menu Warning...

Страница 21: ...n for regular system operation again 4 4 4 System information The version number can be found in the main menu The currently installed software versions are documented in ver sions 4 4 5 System integr...

Страница 22: ...ator IP Config Name Range Explanation DHCP Active Passive Setting the type of address reference Obtain the address from the DHCP server Permanently set IP address Current IP Display of the controller...

Страница 23: ...Coil Status Read Write for BMS 0x0001 BMS release Bit 0 Off 1 On Coil Status Read Write for BMS 0x0002 Al acknowledge Bit 0 Off 1 Execu Input Register Read Only for BMS 3x0001 Feed temp Signed Word 0...

Страница 24: ...ng the selected communication module object name object type object instance description ENG POL908_FF9FAF 8 4169647 DeviceTemplate BACnetClientConfig 10 1 BACnetCovConfig 10 2 ErrorLog 10 3 HistroyLo...

Страница 25: ...w 3 37994 Fluid flow Pump1alarm 3 37430 Alarm pump 1 Pump2alarm 3 2538 Alarm pump 2 Soleflowvolumeqm 2 12675 Fluid volume frostcontroler 2 22201 Frost valve Frostvalve 1 500 defrost valve Operatingmod...

Страница 26: ...necessary If you have connection problems contact the respon sible network administrator 2 Open an HTML5 enabled web browser on the terminal device The following browsers are tested and supported Goog...

Страница 27: ...o the previous page 4 Home Press this button to return to the home page 5 Refresh Updates the browser window 6 Show Hide Trend Shows or hides the online trend window below the user interface To record...

Страница 28: ...Symbol Description 1 Display of the name and version of the controller software Display of the system time of the controller date Display of the system time of the controller time 2 Display of the cu...

Страница 29: ...messages heat recovery operation is maintained and fault messages Both are communicated to the BCS via potential free contact and via bus A malfunction message must be acknowledged on site after the...

Страница 30: ...air work may only be performed by trained and quali fied specialist personnel Warning When working on the HYDROOPT M the device must normally be disconnected from the power supply before hand the main...

Страница 31: ...n for damage and completeness 3 mon 8 4 3 Check temperature and pressure measurement devices for damage and display accuracy plausibility check 3 mon 8 4 4 Check functionality of safety equipment 6 mo...

Страница 32: ...rocesses X 3 Field equipment according to VDMA 24186 4 3 1 Sensors brine temperature sensor magnetic ind flow rate transmitter 3 1 1 Check for proper and functional installation and check ambient cond...

Страница 33: ...idual components If necessary take suitable measures such as adding frost protection taking frost protection measures Before recommissioning follow the points in the commissioning and maintenance chap...

Страница 34: ...m filled with glycol water mixture Glycol content measured ____ Read system fill pressure in idle state ____ bar Pump vented Electrical mains supply Voltage measurement performed Exhaust air shut off...

Страница 35: ...olume m3 h Outdoor air temperature C Temperature according to HRO SUPP C Exhaust air temperature C Temperature according to HRO EXH C BCS power requirement in Outdoor air amount Pump frequency Hz Disp...

Страница 36: ...KO THERM GMBH l Jettingen Scheppach l Germany All rights reserved for AL KO THERM GMBH as well as in the event of applications for industrial property rights This documentation or excerpts thereof ma...

Отзывы: