en
Troubleshooting
22
HW 5000-6000 FMS PREMIUM
Display indicator Cause
Actions
Suction line not in the water,
no flow and no pressure.
Message appears after 90 seconds. After rectifi-
cation of the fault the resetting of the fault mes-
sage is carried out by pushing the SET button.
Running text CHECK WATER INFEED
Pump switches on after de-
lay.
Measuring cycle:
After a specific number of cy-
cles the pump switches on not at the switch-on
pressure, but rather waits approx. 25 seconds to
see if the pressure in the system drops to 1.5 bar.
If the pressure does not drop in this time, the air
filling is OK.
TROUBLESHOOTING
CAUTION!
Disconnect the mains plug before any fault rectification work. Faults in the electrical system
must be rectified by an expert electrician.
Malfunction
Cause
Rectification
Pump motor does not
run
No mains voltage
Check fuses and power supply.
The suction line is not in the
water.
Submerge the end of the suction line into
the water by min. 30 cm.
Suction line blockage
Remove dirt from the suction area and filter.
Pressure line blocked off
Open the closing off devices in the pressure
line.
Pump drawing air into the
suction line
Check all the connections in the suction line
for leaks.
Replace seal ring.
Pump drawing air, water
shortage on suction side.
Switch pump off and allow to cool.
Hose diameter too small
Replace the pressure hose with one with a
larger diameter.
Fault message "Suction
Side" appears
Water volume on the suction
side to little
Throttle back the pump to adapt the flow
rate.
Fault message "TOP
UP 1.5 BAR" appears.
Low air pressure in the sto-
rage vessel
Top up the air in the storage vessel. (Set the
diaphragm pressure to 1.5 bar).
Running text TOP UP 1.5 BAR
ADVICE
If the faults cannot be rectified please contact our Customer Service Department.
Содержание HW 5000 FMS Premium
Страница 4: ...D 4 HW 5000 6000 FMS PREMIUM...
Страница 203: ...467777_d 203 29 30 MODE 31 SET INOX INOX ADVICE 35 C ADVICE 15 20 90 E 29 MODE 30 SET 31...
Страница 208: ...ru 208 HW 5000 6000 FMS PREMIUM X SET 3 1 5 90 SET MODE MODE...
Страница 209: ...467777_d 209 MODE SET 3 MODE 7 SET MODE 29 SET 29 X 1 5 SET 1 8 1 5 1 5 SET 1 5...
Страница 210: ...ru 210 HW 5000 6000 FMS PREMIUM 90 SET 25 1 5 30...
Страница 211: ...467777_d 211 1 5 1 5 1 50 ADVICE xxx xxx x...
Страница 214: ...uk 214 HW 5000 6000 FMS PREMIUM 29 30 31 INOX INOX ADVICE 35 C ADVICE 15 20 90 E 29 30 31...
Страница 215: ...467777_d 215 30 DIN VDE 0100 737 738 702 10 A 10 30 1 5 2 1 2 3 A 7 4 ADVICE 1 B 17 30 2 A 10 3 4 ADVICE 4 1 AL KO...
Страница 217: ...467777_d 217 ADVICE 90 B 17 A 1 1 2 ADVICE 10 1 2 3 1 5 1 5 ADVICE 1 2 3 4 A 6 1 A 6 2 A 1 C 15 D 3 C 16 C 17 A 2...
Страница 219: ...467777_d 219 3 30 X 3 1 5 90...
Страница 220: ...uk 220 HW 5000 6000 FMS PREMIUM 3 ECO 7 ECO 29 29...
Страница 221: ...467777_d 221 1 5 1 8 1 5 1 5 1 5 90 25 1 5 30...
Страница 222: ...uk 222 HW 5000 6000 FMS PREMIUM 1 5 1 5 1 5 ADVICE...
Страница 224: ...D ETK HW 5000 FMS 224 HW 5000 6000 FMS PREMIUM ETK HW 5000 FMS Art Nr 112 851...
Страница 225: ...ETK HW 5000 FMS 467777_d 225 ETK HW 5000 FMS Art Nr 112 851...
Страница 226: ...D ETK HW 6000 FMS 226 HW 5000 6000 FMS PREMIUM ETK HW 6000 FMS Art Nr 112 852...
Страница 227: ...ETK HW 6000 FMS 467777_d 227 ETK HW 6000 FMS Art Nr 112 852...
Страница 228: ...D ETK HW 6000 FMS 228 HW 5000 6000 FMS PREMIUM ETK HW 6000 FMS Art Nr 112 852...
Страница 229: ...467777_d 229...
Страница 230: ...D 230 HW 5000 6000 FMS PREMIUM...
Страница 231: ...467777_d 231...
Страница 232: ......