Venturi nozzle:
Instructions for use:
1. Commissioning
Observe the safety instructions !
First of all, choose a well-suited installation position for your water-ozone generator. The following factors are
important for this:
-
The unit must have a secure stand
-
The operating area should be dust-free and as dry as possible. (In any case below 65% r.l.)
-
Make sure that the ozone generator is always placed high enough above the water surface if you are feeding
ozone into a basin (vessel)! Ideally, we recommend a distance of about one metre above the surface.
-
If the ozone is integrated into a watercourse by means of a venturi nozzle, make sure at all times that all
connections are properly connected and that no water (no liquid) can get into the ozone unit !
Insert the mains plug properly into the socket.
Switch the ozone generator ON with the operating switch. The red light of the operating light indicates that the
water ozone generator is switched on and air (ozone) is flowing out of the ozone outlet at the front.
Now
select/adjust the ozone strength with the stepless ozone regulator. To do this, turn the control clockwise to increase
the ozone output. When the controller is turned all the way up, this corresponds to full operation and 100% ozone
output.
To reduce the ozone output, turn the knob anti-clockwise. When the knob is turned all the way closed, no more
ozone is produced and clean air flows out of the ozone outlet.
With the Venturi nozzle, the ozone gas can be very
practically integrated into a watercourse.
The venturi nozzle has a valve at the ozone inlet and
when water flows through the venturi nozzle, this valve
is opened by the flow pressure and the ozone mixes
with the flowing water (liquid) at this point !
When connecting, always pay attention to the correct
flow direction of the water (liquid), this is indicated on
the Venturi nozzle with an arrow printed on it.
The technical data of the Venturi nozzle are as
follows:
Length:
153 mm
Ozone (air) connection:
1/4 inch
Water connection:
3/4 inch
Connection
example