Aktakom ATK-2040 Скачать руководство пользователя страница 2

www.tmatlantic.com

 

 
 

 

EN 61010-2-032 
CAT II 600V, CAT III 

300V  

Pollution Degree 2 

 

SYMBOLS showed on the clamp meter or in this manual: 

 

Caution, risk of danger.     

Refer to accompanying documents

 

 

Caution, risk of electric shock.

 

 

Double Insulation

 

 

Application around and removal from 

HAZARDOUS LIVE conductors is permitted.

 

 

Earth (ground) 

 

AC (Alternating Current) 

 

DC (Direct Current) 

 

Both direct and alternating current 

 

Conforms to relevant European Union directives.

 

 

Do not dispose of this clamp meter as unsorted 

municipal waste.    Contact a qualified recycler for 

disposal. 

 
Overvoltage Category I (CAT I): 

E q u i p m e n t   f o r   c o n n e c t i o n   t o   c i r c u i t s   i n   w h i c h   m e a s u r e s   a r e 
taken to limit the transient overvoltages to an appropriate low level. 

Overvoltage Category II (CAT II): 

Energy-consuming equipment to be supplied from the fixed installation.

 

Overvoltage Category III (CAT III): 

Equipment in fixed installations. 

 

SAFETY INFORMATION: (Read First Before Operation) 

Содержание ATK-2040

Страница 1: ...www tmatlantic com ATK 2040 AC DC TRMS Watt Clamp Meter Users Manual...

Страница 2: ...ernating current Conforms to relevant European Union directives Do not dispose of this clamp meter as unsorted municipal waste Contact a qualified recycler for disposal Overvoltage Category I CAT I E...

Страница 3: ...s if they look damaged USE CAUTION when working with high voltages USE CAUTION when measuring the voltages higher than 30VAC rms or 60VDC These voltages pose a shock hazard USE EXTREME CAUTION when wo...

Страница 4: ...igital clamp meter for current measurement 2 One touch zero for DCA adjustment 3 AC DC 240K Watt Measurement 4 Large 3 3 4 digits LCD 5 Fast bargraph display 30 times sec for transient observation 6 F...

Страница 5: ...Crystal Display with maximum indication of 3999 Function symbols units bargraph sign decimal points low battery symbols max min symbols and zero symbol are included 8 Low Battery Symbol When this sym...

Страница 6: ...between the two half jaws d Read the measured value from the LCD display 2 AC Current a Set the rotary switch at 400A AC b Press the trigger to open the jaw and fully enclose the conductor to be measu...

Страница 7: ...e of the wire to the load 3 Select the range to Voltage AC or DC and check the voltage reading 4 Select the range to Current AC or DC and check the current reading 5 Select appropriate Watt range 40KW...

Страница 8: ...ll be displayed and updated The LCD display toggles between the MAX and MIN values To exit MAX MIN function press and hold the MAX MIN button for more than 2 seconds If MAX MIN button is pressed the Z...

Страница 9: ...nge Resolution Accuracy Overload Protection 400V 0 1V 1 0 2dgts DC 800V AC Voltage Input Impedance 10M True RMS Crest Factor 4 Accuracy Overload Protection Range Resolution 50 60 Hz 40 1KHz 600V 1V 1...

Страница 10: ...rom the clamp meter B Remove the screw of the battery compartment C Lift and remove the battery compartment D Remove the old batteries E Insert two new 1 5V SUM 3 batteries F Replace the battery compa...

Отзывы: