![Aktakom ATK-2021B Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/aktakom/atk-2021b/atk-2021b_user-manual_2886759014.webp)
12
4. Specifications(23
°
C ± 5
°
C )
DC Current:
Range
Resolution
Accuracy
Overload Protection
40 A
10mA
±1.5%±2dgts
DC 400A
0-150 A
100mA
±1.5%±2dgts
DC 400A
150-200 A
100mA
±2.2%±2dgts
DC 400A
AC Current:
Accuracy
Range
Resolution
50/60 Hz
40 - 1KHz
Overload
Protection
40A
10mA
±1.5%±3dgts ±2.0%±4dgts
AC 400A
0-150A
100mA
±1.5%±3dgts ±2.0%±4dgts
AC 400A
150-200A
100mA
±2.2%±3dgts ±2.5%±4dgts
AC 400A
DC Voltage:
(Overload Protection: 600V)
Range
Resolution
Accuracy
Input Impedance
400mV
0.1 mV
±1.5%±3dgts
2.3M
Ω
4V
1 mV
±1.5%±3dgts
2.3M
Ω
40V
10 mV
±1.5%±3dgts
2.3M
Ω
400V
100 mV
±1.5%±3dgts
2.3M
Ω
600V
1V
±1.5%±3dgts
2.3M
Ω
AC Voltage:
(Input Impedance: 2.3 M
Ω)
Accuracy
Range
Resolution
50/60 Hz
40 - 1KHz
Overload
Protection
0.01-4V
1mV
±1.5%±5dgts ±2.0%±5dgts
AC 800V
40V
10mV
±1.5%±5dgts ±2.0%±5dgts
AC 800V
400V
100mV
±1.5%±5dgts ±2.0%±5dgts
AC 800V
600V
1V
±1.5%±5dgts ±2.0%±5dgts
AC 800V
¹
400mV range is not designed for AC measurement.
Continuity:
(open voltage 0.4V, Overload Protection AC 600V)
Range
Resolution
Accuracy
Beeping
40-400
Ω
0.1
Ω
±1.0%±2dgts
<10.0
Ω
(approx.)
www.tmatlantic.com