SAFETY PRECAUTIONS 

These instruments fulfill the regulations of CE-LVD (EN-61010:2001) 

and CE-EMC (EN-55022:1998/+A1:2000; EN 55024:1998; EN61000-3-

2:2000; EN61000-3-3:1995) 

To ensure safe operation of the equipment and eliminate the danger 

of serious injury due to short-circuit (arcing), the following safety 

precautions must be observed. 

Damages resulting from failure to observe these safety precautions are 

exempt from any legal claims whatever. 

 

Prior to connection of the equipment to the mains outlet, check 

that the available mains voltage corresponds to the voltage setting 

of the equipment. 

 

Connect the mains plug of the equipment only to a mains outlet 

with earth connection. 

 

Do not place the equipment on damp or wet surfaces. 

 

Do not subject the equipment to direct sunlight or extreme 

temperatures. 

 

Do not subject the equipment to extreme humidity or dampness 

 

Replace a defective fuse only with a fuse of the original rating. 

Never short circuit fuse or fuse housing 

 

Do not exceed the maximum permissible input rating. 

 

Conduct measuring works only in dry clothing and in rubber shoes, 

i.e. on isolating mats. 

 

Comply with the warning labels and other info on the equipment. 

 

Do not insert metal objects into the equipment by way of the 

ventilation slots 

 

Do not place water-filled containers on the equipment (danger of 

short-circuit in case of knock over of the container) 

 

Do not operate the equipment near strong magnetic fields (motors, 

transformer etc.) 

 

Do not subject the equipment to shocks or strong vibrations 

 

Keep hot soldering iron or guns away from the equipment 

 

Allow the equipment to stabilize at room temperature before 

taking up measurement (important for exact measurement) 

 

Do not modify the equipment in any way 

Содержание ATH-2235

Страница 1: ...User s Manual DC POWER SUPPLIES ATH 2235 ATH 2243 ATH 3231 ATH 3232 ATH 4012 Thank you for choosing AKTAKOM Power Supply www tmatlantic com...

Страница 2: ...uipment to direct sunlight or extreme temperatures Do not subject the equipment to extreme humidity or dampness Replace a defective fuse only with a fuse of the original rating Never short circuit fus...

Страница 3: ...lies have three ways output Of which two ways are adjustable and one way is fixed The two adjustable outputs can also be selected for constant voltage or constant current designed in high stability an...

Страница 4: ...gulation Two adjustable output CV 1 x 10 4 3mV CC 2 x 10 3 3mA Fixed output 10mV 1 4 Load regulation Two adjustable outputs CV 1 x 10 4 2 mV I 3 A CV 1 x 10 4 5 mV I 3 A CC 2 x 10 3 3 mA I 3 A CC 2 x...

Страница 5: ...ng slave output current by analog meter or LED LCD 6 Volt display indicating slave output voltage by analog meter or LED LCD 7 Control switch for selecting the two adjustable outputs independent serie...

Страница 6: ...put 2 2 1 1 Set 7 and 9 switch to spring out position 2 2 1 2 When the adjustable output is used as CV output first should rotate clockwise the CC adjustment 2 and 17 to maximum then turn on power swi...

Страница 7: ...onnected is series 2 2 2 3 When the two outputs are in series the voltage is controlled by master output but current adjustment of two outputs is still independent Therefore attention should be paid t...

Страница 8: ...ter is 2 5 class To get more accurate measuring value you should calibrate by external circuit with precision measuring instrument 3 CAUTION 3 1 This unit has excellent protection function 5V output h...

Отзывы: