or VDC. 

This symbol adjacent to one or more 

terminals identifies them as being 

associated with ranges that may, in 

normal use, be subjected to 

particularly hazardous voltages. For 

maximum safety, the meter and its test 

leads should not be handled when 

these terminals are energized. 

 

 

CONTROLS AND JACKS 

 
 

COM

MAX

10A

15 min.

every

 MAX

Ω

V

C

F

8

9

5

1

7

6

3

4

2

10

11

 
 

1.

 

6000 count Liquid Crystal Display with symbolic signs 

2.

 

Function switch 

3.

 

10A (positive) input jack for 10A DC or AC     

measurements 

4.

 

COM (negative) input jack 

5.

 

Positive input jack 

6.

 

HOLD & Backlight pushbutton   

7.

 

Max/Min pushbutton 

8.

 

Range/   .Diode pushbutton 

9.

 

HZ/% pushbutton 

10.

 

AC Voltage Detector Sensor 

11.

 

AC Voltage Detector indicator light 

 

SYMBOLS AND ANNUNCIATORS 

 Continuity 

 BAT 

Low Battery 

 Diode 

 HOLD 

Data Hold 

 AUTO 

AutoRanging 

    AC 

Alternating Current or Voltage 

  DC 

Direct Current or Voltage

 

 

 

SPECIFICATIONS 

The instrument complies with: 

EN61010-1. 

Insulation: 

Class2, Double insulation. 

Overvoltage category: 

CATIII 600V, CATII 1000V. 

Display:

 6000 counts LCD display with function 

indication. 

Polarity:

 Automatic, (-) negative polarity indication. 

Overrange:

 “OL” mark indication. 

AC Response

: True RMS (50 Hz or 60 Hz) 

True RMS: 

The term stands for 

“Root-Mean-Square,” which represents the method of 

calculation of the voltage or current value. Average 

responding multimeters are calibrated to read 

correctly only on sine waves and they will read 

inaccurately on non-sine wave or distorted signals. 

True rms meters read accurately on either type of 

signal. 

Low battery indication:

 The “   ” is displayed 

when the battery voltage drops below the operating 

level. 

Measurement rate: 

2 times per second, nominal. 

Auto power off:

 Meter automatically shuts down 

after approx. 15 minutes of inactivity. 

Operating environment:

 0 oC to 50 oC (32 oF to 122 

oF) at < 70 % relative humidity. 

Storage temperature:

 -20 oC to 60 oC (-4 oF to 140 

oF) at < 80 % relative humidity. 

For inside use, max height: 

2000m 

Pollution degree:

 2

 

Power: 

  One 9V battery , NEDA 1604, IEC 6F22. 

Dimensions:

 150 (H) x 70 (W) x 48 (D) mm 

Weight: Approx.:

255g. 

 

Содержание AMM-1032

Страница 1: ...the multimeter may damage the meter and expose the operator to a shock hazard Always recognize the meter voltage limits as stated on the front of the meter Never apply voltage or current to the meter...

Страница 2: ...nsulation Class2 Double insulation Overvoltage category CATIII 600V CATII 1000V Display 6000 counts LCD display with function indication Polarity Automatic negative polarity indication Overrange OL ma...

Страница 3: ...Maximum Input 600V dc or 600V ac rms Capacitance Auto ranging Range Resolution Accuracy 40 00nF 10pF 5 0 of rdg 50 dgts 400 0nF 0 1nF 4 000uF 1nF 40 00uF 10nF 3 0 of rdg 5 dgts 400 0uF 0 1uF 5 0 of r...

Страница 4: ...AX will appear The meter will display and hold the maximum reading and will update only when a new max occurs 2 Press the MAX MIN key again and the display icon MIN will appear The meter will display...

Страница 5: ...asurements set the function switch to the DC 10A position and insert the red test lead banana plug into the 10A jack 3 Remove power from the circuit under test then open up the circuit at the point wh...

Страница 6: ...l appears in the display 3 Insert the black test lead banana plug into the negative jack COM and the red test lead banana plug into the positive jack 4 Touch the test probe tips to the diode or semico...

Страница 7: ...l 3 Dispose of the old battery properly WARNING To avoid electric shock do not operate your meter until the battery door is in place and fastened securely BATTERY INSTALLATION WARNING To avoid electri...

Отзывы: